background image

Swing Gate Operator

FAAC International Inc.

Headquarter & East Coast Operations

5151 Sunbeam Road

Suites 9-11

Jacksonville, FL 32257

Tel. 866 925 3222

www.faacusa.com

FAAC International Inc.

West Coast Operations

357 South Acacia Avenue

Unit 357

Fullerton, CA 92831

Tel. 800 221 8278

415 L LS 24V

UL325 - UL991

Содержание 415 L LS 24V

Страница 1: ...rter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 866 925 3222 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Unit 357 Fullerton...

Страница 2: ...n Instructions 3 General Safety Precautions 4 UL325 Gate Operator Classifications 5 Installing the Warning Signs 5 1 DESCRIPTION 6 2 DIMENSIONS 6 3 TECHNICAL SPECIFICATIONS 7 4 INSTALLATION 7 4 1 Elec...

Страница 3: ...set buttons must be located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily seen wi...

Страница 4: ...sonable use If a gate system component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system as...

Страница 5: ...ngs such as factories loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use i...

Страница 6: ...icle access Avoid any other use what so ever NOTES Use suitable conduit to lay electric cables To avoid any kind of interference always use individual sheaths to separate low voltage accessories and c...

Страница 7: ...afety of the automated system Before installing the 415 Operator prepare the gate for the operator by performing the following Make sure that the gate structure is solidly built Add rein forcing cross...

Страница 8: ...erator cut a niche into the pillar as shown in Fig 5 in order to maintain the A dimension as determined The dimensions of the niche should enable easy installa tion rotation and operation of the relea...

Страница 9: ...friction or hin drances Ensure that it opens completely and stops at the mechanical travel stops 12 Perform the necessary corrective measures and repeat from Step 11 13 Temporarily release the operat...

Страница 10: ...ustment range Limit switches adjustment is carried out as follows 1 Unscrew the upper fastening screw Fig 18 Ref A and remove the cap Fig 18 Ref B 2 To adjust the closing limit switch FCC turn the adj...

Страница 11: ...en in the event of a power outage 2 Slide the protective cap Fig 21 Ref 1 3 Insert the key and turn it 90 Fig 21 Ref 2 4 To release the operator turn the control lever 180 in the direction indicated b...

Страница 12: ...04 7182075 SHORT PIN 05 N A HEX NUT 06 7221115 REAR FORK 07 716148 UPPER BODY 08 428403 MANUAL RELEASE ASSEMBLY 09 60202145 MANUAL RELEASE CAM 10 60202155 MANUAL RELEASE LEVER 11 716151 PROTECTIVE COV...

Страница 13: ...ower supply Programming With trimmers dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper...

Страница 14: ...D 24 Vdc negative 8 24 24 Vdc positive 9 OUT Programmable output See DS1 SW 11 12 10 FCA 1 Open limit switch Motor 1 11 GND 24 Vdc negative 12 FCC 1 Close limit switch Motor 1 13 FCA 2 Open limit swit...

Страница 15: ...d the closing movements The E024U board allows the connection of several safety devices for example photocells With photocells you can activate the FAILSAFE function which before each movement of the...

Страница 16: ...e power supply of the transmitters to OUT pin 9 and set dip switch 11 and 12 to ON on DS1 When using the FAIL SAFE mode also the safety inputs not used FSW CL FSW OP must be connected to OUT pin No 9...

Страница 17: ...onnection of one pair of opening photocells Other optional safety devices to connect in series Fig A10 Fig A11 Fig A12 To use the FAIL SAFE mode connect the ne gative power supply of the transmitters...

Страница 18: ...move ment a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then clo ses automatically A command during the pause time holds the gate...

Страница 19: ...the original starting position If in the successive movement an obstacle is detected again the board will be put in alarm mode and won t take any more commands until the STOP input is activated Alarm...

Страница 20: ...afety With SW8 OFF the gate movement will be reversed as soon as the safety is active with SW8 ON the gate will stop when the safety is active and it will reverse only when the safety is deactivated a...

Страница 21: ...FF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec before an opening ON SE...

Страница 22: ...key not present USB key inserted and software Update in progress DON T Remove the USB key 7 RESERVED 8 LED DL 14 OPEN A INPUT N O OPEN A active OPEN A not active LED DL 15 OPEN B INPUT N O OPEN B act...

Страница 23: ...re correct replace the encoder 6 FAIL SAFE FAILED Verify the photocells wiring and alignement 7 BOARD THERMAL PROTECTION ACTIVE Turn off the board and wait until the components cool down 8 MAX RUN TIM...

Страница 24: ...or the remote that is already stored in memory Leaf 1 starts to slow down and stops when it reaches the mechanical stop or FCC1 12 The manual time learning procedure is complete 15 15 32 6 7 32 17 15...

Страница 25: ...eset for 115V at the fac tory consult with FAAC Tecnical Support for 230V wiring options 230V 115V The E024U board allows the connection of a 24V backup bat tery to provide power to operate the gate d...

Страница 26: ...release saves CLOSE OPEN IN PAUSE reloads pause time 1 reloads pause time of released leaf recloses leaves immediately stops operation no effect recharges pause time CLOSE disa bled recharges pause t...

Страница 27: ...operation no effect recharges pause time CLOSE disa bled recharges pause time CLOSE disa bled CLOSING reopens leaves immediately reopens leaves immediately no effect stops operation no effect reverse...

Страница 28: ...ed CLOSING opens the leaves no effect no effect stops operation no effect reverses at opening stops and opens at release saves OPEN CLOSE BLOCKED opens the leaves closes leaves closes leaves no effect...

Страница 29: ...ct s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more s...

Отзывы: