Connecting sensitive edge and/or internal photocells.
With DSW2 Dip switch 1 OFF, programmable input SOP is configured as normally closed for the use of a non-resistive sensitive edge N.C. With the
sensitive edge not engaged LED DL6 must be on. If not used, jumper between COM and SOP.
With DSW2 Dip switch 1 ON, programmable input SOP is configured for the use of a resistive sensitive edge 8K2. With the sensitive edge not engaged
LED DL6 must be on. If not used,
set DSW2 Dip switch 1 to OFF and jumper between terminal COM and SOP.
The triggering of input SOP, during closing, inverts and immediately stops motion. After the edge is disengaged, the gate remains still until a new control
is given. The triggering of input SOP, during opening, inverts and immediately stops motion. After the edge is disengaged, gate closing motion resumes.
Edge with
electro-
mechanical
switch
Resistive edge
8.2 kOhm
DSW2
DIP 1 OFF
DSW2
DIP 1 ON
Electrical connection with Photo-test function active
With DSW1 Dip switch 8 ON, programmable input P.OUT controls the operation of the safety devices.
Internal
photocell
Internal
photocell
External
photocell
External
photocell
Acces24VDC
Accessories -24VDC
Safety device when closing N.C.
Safety device when
opening and closing N.C.
Safety test +24VDC