6. Electrical wiring.
Description of terminals:
Terminal block M1
Terminal number
Board marking
Description
1
P.IN
Input (N.C.) for opening and closing safety devices
(momentary stop)
2
SEQ
Push button (N.O.) for opening and closing (sequential or start)
3
STOP
Push button (N.C.) for stop
4
PED
Push button (N.O.) for pedestrian opening
5
SCL
Input (N.C.) for closing safety devices (reopening)
6
SOP
Programmable input for non resistive (N.C.) or resistive 8K2 sensitive edge
7
LSC
Input (N.C.) for left limit switch (activated with right-hand cam)
8
LSO
Input (N.C.) for right limit switch (activated with left-hand cam)
9
COM
Common inputs and indicator light (negative)
10
+AS
Positive for 24 VDC accessories power supply
11
-AS
Negative for 24 VDC accessories power supply
12
+P.OUT
24VDC positive programmable output for safety test or 2
nd
radio channel
13
+WL
Positive for indicator light 24V, 2W max
Terminal block M2
14
MOP
Motor opening direction output
15
MCL
Motor closing direction output
16
MCOM
Common motor winding output
17
FL
Flashing lamp 230/120 V 50 Hz 25 W max (NEUTRAL)
18
FL
Flashing lamp 230/120 V 50 Hz 25 W max (PHASE)
19
N
Input for 230/120 V 50 Hz line (NEUTRAL)
20
L
Input for 230/120 V 50 Hz line (PHASE)
21
Input for earth connection
The sum of the absorptions of the 24VDC accessories must not exceed 300 mA
Wiring for power supply line, flashing lamp and electric motor:
PHASE
NEUTRAL
OPENING
COMMON MOTOR
CLOSING
PHASE FLASHING
NEUTRAL FLASHING
EARTH
230 VAC
Capacitor
LIMIT SWITCH
COMMON
RIGHT LIMIT SWITCH N.C.
LEFT LIMIT SWITCH N.C.
COMMON (NEGATIVE)
230/120 VAC
17
SL230.T - SL230.T.120
EN