To cancel all the associations, next to any code press
0
+
, and
when this message is displayed:
press
1
and
to confirm.
After confirming the operation, wait for completion of the cancel-
lation process.
Default: no association.
Note:
using the numeric keypad to select the ID in vertical con-
figuration type in the number of the indoor unit (between 1 and
200) and between 201 and 204 for concierge switchboards. In
horizontal configuration, type in the code of the indoor units
delimited by the window and valid in relation to the number of
indoor units per router, see table 3 (provided on the following
pages), or type in the IDs of switchboards between 40001 and
40008, which by default correspond to the IDs of the switch-
boards of router 1 and router 2, otherwise the IDs among those
configured in Switchboard position (see paragraph 4.2).
A code without remapping cannot be called by this electronic
unit, unless you have configured either a traditional button or
one of
and
.
2.6 - Search
the
entire
contacts
list
With this item, the electronic unit can be configured to scroll
through the entire contacts list by entering a blank name as the
search string. Normally, at least the first letter of the name to be
searched should be entered With the FLAG selected, press
then
or
to see respectively the first and last names in
the contacts list, whatever the initial letter.
The
and
buttons can then be used to scroll through the
entire contacts list. To enable the setting, press
1
and
con-
firm with
. To deactivate the function, press
0
+
and
.
In the case of Horizontal Installation other codes that change the
function are possible. They are:
BUTTON
SEARCH THE ENTIRE CONTACTS LIST...
2
ABC
NO, and with the keypad calls are allowed only if
there is a corresponding name in the contacts list.
3
DEF
YES, and with the keypad calls are allowed only
if there is a corresponding name in the contacts
list.
4
GHI
NO, and with the keypad calls are allowed only if
the ID is within the start-end range.
5
JKL
YES, and with the keypad calls are allowed only
if the ID is within the start-end range.
Default: No
2.7 - Device names
R
The electronic units have an electronic contacts list for 208 [max
1008] users. Each user can be assigned two names (a and b)
of 15 visible characters each (plus a sixteenth character not vis-
ible, exclusively for compatibility with the 8000 series panels).
Use the
buttons or key in the
to select
one of the 208 [max 1008] users.
Each user is matched with two names (
a
and
b
), to be selected
with buttons
. Having located the required line, press
the
button to change the value. Once change mode is acti-
vated, the blinking cursor will show where to enter the character.
To enter characters / symbols, use buttons
0
+
to
9
WXYZ
. Each
button has more than one character/symbol associated with
it (see table 3). To find the desired symbol, press the button
repeatedly before the end of the 2 second timeout, which is
renewed with each press of the button. If the symbol entered
previously was an upper case character, even if the button is
changed, the function will restart with upper case. If the symbol
was lower case, the function will restart with lower case. If the
symbol was a digit, the function will restart with a digit. To enter
a character / symbol located on a different button from the one
previously pressed, it is not necessary to wait for the end of
the timeout.
When entering symbols, the
and
buttons can be used
to scroll along the line, and the
R
button to delete the char-
acter to the left of the cursor. Press
to confirm the change.
After confirmation, the electronic unit will check whether or not
the name entered is already used in another position. If it is
already used the display will show a message similar to this:
and it will be necessary to enter another name. When searching
for uniqueness, uppercase and lowercase letters are distinct.
Whereas when searching for a call there is no distinction.
Note:
using the numeric keypad to select the ID in vertical con-
figuration type in the number of the indoor unit (between 1 and
200) and between 201 and 204 for concierge switchboards. In
horizontal configuration, type in the code of the indoor units
delimited by the window and valid in relation to the number of
indoor units per router, see table 3 (provided on the following
pages), or type in the IDs of switchboards between 40001 and
40008, which by default correspond to the IDs of the switch-
boards of router 1 and router 2, otherwise the IDs among those
configured in Switchboard position (see paragraph 4.2).
Default: blank.
2.8 - Programming password
Sets the password for access to configuration from keypad.
Enter the new password using buttons
0
+
to
9
WXYZ
. Press
to confirm the change.
Default: 654321
2.9 - Answer time
This is the interval of time, expressed in seconds, that the elec-
tronic unit waits from the end of the call signal until there is an
answer from the indoor unit. If there is no response within the
"answer time", the electronic unit ends the call. If the indoor unit