13F4, 13A4, 13A4.B - 13F7, 13A7, 13A7.B
Parameter
configuration
Changes are made connecting one electronic unit at a time.
In systems with several electronic units, one unit must be
identified as a
MASTER
and the other units as
SLAVE
units,
regardless of model or type (alphanumeric, buttons, landing).
All entrance panels are supplied with the electronic unit set as
MASTER
(ID = 1).
Procedure for accessing parameter configuration
mode
You have to start with the electronic unit in a state of rest: there
must be no calls in progress, no self-starting or anything similar.
Press buttons
R
+
4
GHI
. Release the buttons.
Key in the password, by default
6
MNO
5
JKL
4
GHI
3
DEF
2
ABC
1
. Every time a button is pressed there will be a short “beep”, an
asterisk “*” appears on the display, and there are a further 25 s
in which to press the next button. If you let the timeout elapse,
the electronic unit
will return to rest.
After entering the password, press the
button. If the pass-
word is correct, the electronic unit goes into parameter configu-
ration mode. If the password is wrong, the electronic unit exits
the procedure and reverts to at-rest status. The operation must
be repeated.
Note:
The information that appears in square brackets refers to
the case of active Horizontal Installation, paragraph 1.2.
Parameter default settings
Table 2
Parameter
Default
1.0
Message language
Italian
1.1
Entrance panel ID
1
1.2
Installation
Vertical Bus
1.3
Initial ID (+)
1
1.4
Final ID (+)
1000
1.4A
IU per router (+)
200
1.5
First button ID
1
1.6
Button remapping
HW
1.7
Single buttons
Yes
1.8
No. coding digits
Sequential coding
1.9
Lock code
R+1
2.0
Preferential code
Not assigned
2.1
Preferential code
Not assigned
2.2
Lock codes
Not assigned
2.3
F1 codes
Not assigned
2.4
F2 codes
Not assigned
2.5
No. Dev. (
-)
Not assigned
Parameter
Default
2.6
Search all contacts
No
2.7
Contacts Name
Not assigned
2.8
Program Password
654321
2.9
Answer time
30 s
3.0
Conversation time
120s
3.1
Self-start time
10 s
3.2
Lock time
1 s
3.3
Function 1 Time
1 s
3.4
Function 2 Time
1 s
3.5
Door Open send time
1 Min.
3.6
External volume
3
3.7
Internal volume
3
3.8
Balancing
8
3.9
Chime Volume
0
3.10 Lock interlock
No
3.11 Enabling
Direct enabled, Com-
mon disabled
4.0
Entrance panel chime
Yes
4.1
No. chime cycles
2
4.2
Switchboard pb
Not assigned
4.3
Button Audio call
Not assigned
4.4
Com. lock
Not assigned
4.5
F1 common
Not assigned
4.6
F2 common
Not assigned
4.7
Disable SB search (*)
Yes
4.8
Disable self-start (*)
No
4.9
Seq. Self-start (*)
Not assigned
4.10 Date and Time format
01/01/2014 00:00
5.0
Clock
01/01/13 00:00
5.1
Enable timed codes
No
5.2
First Time Call
0
5.3
Last Time Call
0
5.4
Band
Not assigned
5.5
Device (°)
5.6
Button (°)
Notes:
(*) configurable only with MASTER or horizontal
electronic unit, (°) only in the vertical configuration, (+) only
in the horizontal configuration, (-) only if No. Coding Digits
is not
Sequential.