Figure 8.
Vent System Components and Termination Kits
Step 3. Installing the Vent System
A. Vent System Approvals
These models have vent starting collars on both the top
and the back of the unit. Depending upon the installation,
decide which ONE set of starting collars will be used to
attach the vent system. The starting collar sealing cap
must remain on the starting collar NOT used.
These models use SL-D-series, direct vent components
when using the
TOP
vent collars. This pipe is tested and
listed as an approved component of the fireplace. The pipe
is tested to be run inside an enclosed wall. There is no
requirement for inspection openings at each joint within
the wall. There is no required pitch for horizontal vent runs.
These models also use D-series direct vent components
when using the
REAR
vent collars.
The flame and ember appearance may vary based on the
type of fuel burned and the venting configuration used.
Vent System
Termination Kits
Vent System Components
WARNING: YOU MUST NOT MIX D-SERIES
AND SL D-SERIES COMPONENTS IN ANY
VENT SYSTEM CONFIGURATION.
Identifying Vent Components
Approved vent system components are labeled for identi-
fication.
NO OTHER VENTING SYSTEMS OR COMPO-
NENTS MAY BE USED
. Detailed installation instructions
are included with each vent termination kit and should be
used in conjunction with this
Installers Guide
. Figure 8
shows vent system components and terminations.
The vent systems installed on this gas fireplace may in-
clude one, two, or three 90° elbow assemblies. The rela-
tionships of vertical rise to horizontal run in vent configura-
tions using 90° elbows
MUST BE
strictly adhered to. The
rise to run relationships are shown in the venting drawings
and tables. Refer to the diagrams on the next several pages.
NOTE: Two 45° elbows may be used in place of one
90° elbow. Maximum and minimum rise to run ratios
must always be maintained in the vent system when
using 45° elbows.
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
VERTICAL
TERMINATION
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
SLK-991DA
SLK-01TRD
SLK-01TRF*
DVK-TVCD
SL D-SERIES
D-SERIES
DVK-01TRD
DVK-01TRF*
DV-FLEX2-01TRF
SL-FLEX2-01TRF
*
For use with flex vent only.