Component Testing (cont.)
240 Volts
208 Volts
Current (AMPS)
Current (AMPS)
Conv Fan
Low Speed Reverse
Conv Fan
High Speed Reverse
Latch Motor
This parameter will cycle the EOC lock relay and operate
the lock motor. Press “MIN/SEC TIMER” and LAtC will show in
the display. Press “MIN/SEC TIMER” again to lock and un-lock the
door and the display will show the current state. When
in-between switch contacts three dashes will show in display.
When in-between switch contacts, three dash’s will show in display.
To Lock
Door
To Unlock
Door
Caution:
Door must be installed and closed while performing LATCH MOTOR test or damage may occur to
latch assembly.
© 2012 Viking Preferred Service
21
Diagnostics
Motor
Advances
Motor
Stops
Motor
Advances
Motor
Stops
Press
MIN/SEC
TIMER
twice
Press
MIN/SEC
TIMER
twice