© 2012 Viking Preferred Service
19
Diagnostics
Component Testing
On the following tests, when you have selected a particular component, press “MIN/SEC TIMER” to activate. The
display will change to AC current. Press “MIN/SEC TIMER” one more time to turn it off and go back to the test
selection menu, or rotate the “SET KNOB” to move to the next component in the menu. Values are approximate.
240 Volts
280 Volts
Current (AMPS)
Current (AMPS)
Inner Bake
Note:
Inner bake is
not used on RDDOE and
RDSOE series ovens.
Outer Bake
Press “MIN/SEC TIMER”
to operate Outer
bake element.
Inner Broil
Press “MIN/SEC TIMER”
to operate Inner
broil element.
Outer Broil
Press “MIN/SEC TIMER”
to operate Outer
broil element.
Convection
Press “MIN/SEC TIMER”
to operate Convection
element.
Convection Fan Hi F
Press “MIN/SEC TIMER”
to operate the
Conv fan high.
Содержание RDSOE306SS
Страница 23: ... 2012 Viking Preferred Service 23 Service Diagnostics and Procedures Parts Location Relay Board ...
Страница 37: ... 2012 Viking Preferred Service 37 Service Diagnostics and Procedures Parts Location Oven Top ...
Страница 44: ... 2012 Viking Preferred Service 44 Service Diagnostics and Procedures Parts Location Oven Note Upper oven shown ...
Страница 58: ... 2012 Viking Preferred Service 58 Wiring and Schematics ...
Страница 59: ... 2012 Viking Preferred Service 59 Wiring and Schematics Wiring Schematic RDSOE306 RDDOE306 Upper Oven ...
Страница 60: ... 2012 Viking Preferred Service 60 Wiring and Schematics Wiring Schematic RDDOE306 Lower Oven ...