© 2012 Viking Preferred Service
20
Diagnostics
Component Testing (cont.)
240
Volts
208
Volts
Current (AMPS)
Current (AMPS)
Convection Fan Lo F
Press “MIN/SEC TIMER”
to operate the
Conv fan low.
Cooling Fan High
Press “MIN/SEC TIMER”
to operate
Cooling fan high.
Cooling Fan Low
Press “MIN/SEC TIMER”
to operate Cooling
fan low.
Note:
Same speed as
High fan.
RPM’s
Cooling Fan
High Speed–RPM
When “MIN/SEC TIMER” is
depressed, cooling fan
comes on and the RPM’S
are shown in the display.
Cooling Fan
Low Speed–RPM
Lights–Oven
This parameter will cycle
the EOC light relay ON
and OFF with each press
of “MIN/SEC TIMER”, as
well as the display showing
the status.
Press
MIN/SEC
TIMER
Press
MIN/SEC
TIMER
Press
MIN/SEC
TIMER