4

Features Overview

MAC:

18E80FXXXXXX

asdesaxtff

N.C.

 - Black

+ Red

 - Black

+ Red

 Green

 Green

 Green

 White

N.O.

COM.

N.C. (Gray)

N.O. (Yellow)

COM. (Blue)

 Relay 1

Output Contacts

(2A@30VDC/ 250VAC max)

 Relay  2 Output Contacts

(2A@30VDC/ 250VAC max)

 Request for Exit 

(REX) Input

* 3 Gel-Filled Butt

Connectors 

(included)

+ Red

- Black

Black

Black

- Black

+ Red

Speaker

LED

Microphone

Call Switch

MAC Address Label: 

The 

MAC address is a unique 
12 digit number used by 
routers to send network 
traffic to the correct IP 
address.

PoE LAN Port 10/100, 
PoE Class 2 (<6.5 Watts): 

Connect to your LAN via 
RJ45 plug and CAT5 or 
greater twisted pair wire.

Yellow Network Status 
LED: 

Lights steady to 

indicate power and data 
link. Blinks to indicate 
network activity.

Green Unit Status LED

Rear (PCB) View of the

K-1700-IP Entry Phone

White

White

(Power typically not

required for gate controllers)

Doorstrike / 
Magnetic Lock

120V AC

Connect to Optional 

Doorstrike, Mag Lock, 

Gate Controller, etc.

(not

connected)

26 Bit Wiegand Input / Output

For connecting optional Proximity Card 
Readers, see Viking models left and  
above (not included) or program as a 
output to connect to the card reader 
input of an Access Control System

12 VDC Power Output for 

VE-LIGHT, etc. 

(12VDC @ 50mA max)

  

Brown

Violet

White

Model PRX-1 

Proximity Card 
Reader DOD 221

Model PRX-3 

Medium 

Range Proximity Card 
Reader DOD 228

Model PRX-5 

 

125KHz 
Mullion-Mount 
Proximity Card 
Reader with 
Built-In Keypad 
DOD 224

* Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. 

Push Button Switch:

  Push to 

initiate call, push again to 
disconnect. Solid 316 stainless 
steel, internally sealed per IP67.

Speaker Screen:

  Speaker 

screen with 0.018" wide slots to 
prevent punctures from 
paperclips, etc.

Faceplate Material:

  14 gauge 316 

stainless steel. The SS model has 
a #4 brushed finish, the BN model 
has a powder painted finish.

Speaker:

  Mylar speaker with 

rubber gasket to maintain 
water-tight seal and eliminate 
water deterioration.

Blue Call LED:

  Lights steady to 

help locate the button in low light, 
flashes during dialing, then lights 
steady when answered.

Microphone:

  Omni-directional 

microphone with protective 
water-resistant cloth.

Front View of the

K-1700-IP Entry Phone

Call

VIKING

©

Condensation Drain Hole

Mounting Screws:

  (4) 6-32 X 3/4” 

Marine grade 316 stainless steel, 
flat head, T-10 Torx security 
screws and drive bit (included).

Laser Etched Graphics: 

For long 

lasting easy to read graphics. 
Copper metallic on “oil rubbed 
bronze” model K-1700-BN-IP.

1

2

ABC

5

JKL

8

TUV

0

OPER

4

GHI

7

PRS

#

3

DEF

6

MNO

9

WXY

Содержание K-1700-BN-IP

Страница 1: ...one is connected to an apartment or business tenant a built in contact closure may be activated to control an electric gate or door strike Up to 1 000 keyless entry codes may be programmed providing t...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...c 12VDC 50mA max Brown Violet White Model PRX 1 Proximity Card Reader DOD 221 Model PRX 3 Medium Range Proximity Card Reader DOD 228 Model PRX 5 125KHz Mullion Mount Proximity Card Reader with Built I...

Страница 5: ...stucco etc additional caulking may be required Earth Ground the Green Yellow wire using the provided wire nut Black Green White Black Green White To Wiegand Input on K 1700 IP Connect to Ground on En...

Страница 6: ...Hub Available LAN with PoE class 2 6 5 watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM PC Programming Download and install the programmi...

Страница 7: ...ng you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the n...

Страница 8: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 9: ...cting an integer 1 to 4094 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to h...

Страница 10: ...ash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release button Step 4 You can now enter programming by following the steps in section B Step 1 Po...

Страница 11: ...d factory set to ON 23 18 Speaker Volume 0 9 factory set to 3 24 18 Ring Volume 0 9 factory set to 5 25 18 Microphone Volume 0 9 0 Auto factory set to 5 26 18 In Band Audio Call Progress Enabled Disab...

Страница 12: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1700 IP Series Phone being programmed When registered to a...

Страница 13: ...ociated with that Speed Dial Number If there is no answer or a busy signal is detected the K 1700 IP will then dial the Roll Over Phone Number The Primary Phone Number programmed in Index 0 is the num...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...the ability to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call...

Страница 16: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Страница 17: ...second relay activation time is recommended Alarm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered to the SIP server In the event...

Страница 18: ...l truck Factory Setting 5 seconds 26 Microphone Volume Automatic Noise Cancelling Mode This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Delay can be...

Страница 19: ...SIP calls One option is to generate a loud ring sound through the speaker The K 1700 IP Phone can also auto answer a SIP call to transmit a page control the relay or listen to transmit audio from the...

Страница 20: ...he gateway The three beeps can be muted by clicking on Mute Current Next Alarm The Status LED will continue to flash to assist troubleshooting The alarm beeps can also be permanently disabled See Perm...

Страница 21: ...ically only used when Viking Technical Support has sent you updated firmware 43 Import Export The Import Export feature is useful for backing up all the K 1700 IP s programming or for importing progra...

Страница 22: ...nd Toggle To use a keyless entry code the tenant simply dials followed by the entry code on the K 1700 IP s keypad These can be entered before or after pressing the call button After the one time use...

Страница 23: ...nectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc...

Страница 24: ...x7 SS VE 6x7 PNL VE 6x7 PNL SS VE 5x10 VE 5x10 SS VE 5x10 PNL VE 5x10 PNL SS VE 3x5 VE 5x10 NR VE 5x10 NR SS The VE GNP gooseneck pedestals are designed to be used with the VE 5x5 VE 6x7 and VE 5x10 b...

Страница 25: ...hich allow the reader to be conveniently adjusted and leveled To allow both indoor and outdoor operation the electronics are sealed in tamper resistant epoxy potting Concealing the mounting hardware t...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: