Warranty

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries 
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

Product Support: 715-386-8666

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT VIKING TECHNICAL SUPPORT: 715-386-8666

 

Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better 
service, before you call please: 

1

.

  Know the model number, the serial number and what software version you have (see serial label). 

2. 

 Have the Product Manual in front of you. 

3. 

 It is best if you are on site.

TWO YEAR LIMITED WARRANTY

 

      Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any 

authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial 

Street, Hudson, WI., 54016.  Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. 
     This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the 
product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. This warranty does not cover stainless 
steel surfaces that have not been properly maintained. 
     NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR 
IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. 
     EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR 
CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER. 
     EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY 
OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE 
PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED. 
     IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, 
EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH 
PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.

If trouble is experienced with the 

K-1700-IP 

phone, for repair or warranty information, please contact:  

Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016  715-386-8666

 

WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:

 

Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such tests in off-peak hours, such as early morning or late evenings. 

PART 15 LIMITATIONS

 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

 

CANADA

 

This class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.

RETURNING PRODUCT FOR EXCHANGE 

The following procedure is for equipment that has failed out-of-box 
(within 10 days of purchase):

 

1.  

Customer must contact Viking’s Technical Support at 715-386-8666 to 

determine possible causes for the problem. The customer MUST be able to step 
through recommended tests for diagnosis. 

2. 

 If the Technical Support Product Specialist determines that the equipment is 

defective based on the customer's input and troubleshooting, a Return 
Authorization (RA) number will be issued. This number is valid for fourteen (14) 
calendar days from the date of issue. 

3. 

 After obtaining the RA number, return the approved equipment to your 

distributor. Please reference the RA number on the paperwork being shipped 
back with the unit(s), and also the outside of the shipping box. The original 
product boxes are not designed for shipping - an overpack box is required to 
prevent damage in transit. Once your distributor receives the package, they will 
replace the product over the counter at no charge. The distributor will then 
return the product to Viking using the same RA number. 

 

4.  The distributor will NOT exchange this product without first obtaining the 

RA number from you.  If you haven't followed the steps listed in 1, 2 and 3, 
be aware that you will have to pay a restocking charge.

RETURNING PRODUCT FOR REPAIR

 

The following procedure is for equipment that needs repair:

 

1. 

 Customer must contact Viking's Technical Support Department at 715-386-8666 

to obtain a Return Authorization (RA) number.  The customer MUST have a 
complete description of the problem, with all pertinent information regarding the 
defect, such as options set, conditions, symptoms, methods to duplicate 
problem, frequency of failure, etc. 

2. 

 Packing:  Return equipment in original box or in proper packing so that damage 

will not occur while in transit. The original product boxes are not designed for 
shipping - an overpack box is required to prevent damage in transit.

 

Static 

sensitive equipment such as a circuit board should be in an anti-static bag, 
sandwiched between foam and individually boxed. All equipment should be 
wrapped to avoid packing material lodging in or sticking to the equipment. 
Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot 
be accepted. Ship cartons prepaid to:  

 

 

VIKING ELECTRONICS 

1531 INDUSTRIAL STREET 

HUDSON, WI  54016

 

3.

  Return shipping address: Be sure to include your return shipping address inside 

the box. We cannot ship to a PO Box. 

4.

  RA number on carton: In large printing, write the RA number on the outside of 

each carton being returned. 

Содержание K-1700-BN-IP

Страница 1: ...one is connected to an apartment or business tenant a built in contact closure may be activated to control an electric gate or door strike Up to 1 000 keyless entry codes may be programmed providing t...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...c 12VDC 50mA max Brown Violet White Model PRX 1 Proximity Card Reader DOD 221 Model PRX 3 Medium Range Proximity Card Reader DOD 228 Model PRX 5 125KHz Mullion Mount Proximity Card Reader with Built I...

Страница 5: ...stucco etc additional caulking may be required Earth Ground the Green Yellow wire using the provided wire nut Black Green White Black Green White To Wiegand Input on K 1700 IP Connect to Ground on En...

Страница 6: ...Hub Available LAN with PoE class 2 6 5 watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM PC Programming Download and install the programmi...

Страница 7: ...ng you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the n...

Страница 8: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 9: ...cting an integer 1 to 4094 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to h...

Страница 10: ...ash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release button Step 4 You can now enter programming by following the steps in section B Step 1 Po...

Страница 11: ...d factory set to ON 23 18 Speaker Volume 0 9 factory set to 3 24 18 Ring Volume 0 9 factory set to 5 25 18 Microphone Volume 0 9 0 Auto factory set to 5 26 18 In Band Audio Call Progress Enabled Disab...

Страница 12: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1700 IP Series Phone being programmed When registered to a...

Страница 13: ...ociated with that Speed Dial Number If there is no answer or a busy signal is detected the K 1700 IP will then dial the Roll Over Phone Number The Primary Phone Number programmed in Index 0 is the num...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...the ability to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call...

Страница 16: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Страница 17: ...second relay activation time is recommended Alarm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered to the SIP server In the event...

Страница 18: ...l truck Factory Setting 5 seconds 26 Microphone Volume Automatic Noise Cancelling Mode This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Delay can be...

Страница 19: ...SIP calls One option is to generate a loud ring sound through the speaker The K 1700 IP Phone can also auto answer a SIP call to transmit a page control the relay or listen to transmit audio from the...

Страница 20: ...he gateway The three beeps can be muted by clicking on Mute Current Next Alarm The Status LED will continue to flash to assist troubleshooting The alarm beeps can also be permanently disabled See Perm...

Страница 21: ...ically only used when Viking Technical Support has sent you updated firmware 43 Import Export The Import Export feature is useful for backing up all the K 1700 IP s programming or for importing progra...

Страница 22: ...nd Toggle To use a keyless entry code the tenant simply dials followed by the entry code on the K 1700 IP s keypad These can be entered before or after pressing the call button After the one time use...

Страница 23: ...nectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc...

Страница 24: ...x7 SS VE 6x7 PNL VE 6x7 PNL SS VE 5x10 VE 5x10 SS VE 5x10 PNL VE 5x10 PNL SS VE 3x5 VE 5x10 NR VE 5x10 NR SS The VE GNP gooseneck pedestals are designed to be used with the VE 5x5 VE 6x7 and VE 5x10 b...

Страница 25: ...hich allow the reader to be conveniently adjusted and leveled To allow both indoor and outdoor operation the electronics are sealed in tamper resistant epoxy potting Concealing the mounting hardware t...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: