When using date and time logged events or setting the access date and times of keyless codes or proximity cards in 
the Entry Code Database, you must program the unit to your time zone. Example: You are installing the 

K-1700-IP

 in 

the Central standard time zone: Select (UTC - 06:00) CST, which is 6 hours behind Coordinated Universal Time (UTC). 

Factory Setting:

 CST 

14. Select Time Zone

The Daylight Savings Time programming can be enabled or disabled and can be programmed to start on any Sunday 
in March and stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in 
March and ends on the first Sunday in November, with the time changes taking place at 2:00AM local time. 

Factory Setting:

 Enabled

15. Daylight Savings

13. Wiegand Direction

Wiegand Direction allows you to decide if the 26 bit Wiegand connection will be used as an input or an output. The default 
setting for direction is “Inbound” and this is the correct setting if you intend to connect a card reader or Wiegand keypad 
device to the wiegand connections. 
When the direction is set to “outbound”, the 26 bit Wiegand connections become an output and can be connected to the 
card reader input on the access control system. Unprogrammed keyless entry codes dialed by the user on the keypad are 
then sent over the Wiegand output. When the user dials “#” plus a entry code that is not programmed in the Entry Code 
Database, the code dialed by the user is sent over the Weigand output along with the facility code selected. Since Wiegand 
data limits the entry code to 65535 maximum, “#” plus entry codes higher than 65535 are not sent over the Wiegand 
output. When the user dials “#” plus a valid keyless entry code that is programmed in the Entry Code Database, the code 
dialed by the user is not sent over the Wiegand output and the Local / External relay is activated. 

16. Relay 1 or 2 Internal / External

With relay 1 and/or 2 set to “Internal” the 

K-1700-IP

 will activate its on board relays for doorstrike / gate control. Relay 

1 and/or 2 should be set to “External” for higher security installations when using a Viking model 

RC-4A

 remote relay 

controller to activate the doorstrike / gate controller (see page 23).  

Note: 

With relays set to external the internal on 

board relays will also activate at the same time as the external relays.   

Factory Setting:

 Internal

Содержание K-1700-BN-IP

Страница 1: ...one is connected to an apartment or business tenant a built in contact closure may be activated to control an electric gate or door strike Up to 1 000 keyless entry codes may be programmed providing t...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...c 12VDC 50mA max Brown Violet White Model PRX 1 Proximity Card Reader DOD 221 Model PRX 3 Medium Range Proximity Card Reader DOD 228 Model PRX 5 125KHz Mullion Mount Proximity Card Reader with Built I...

Страница 5: ...stucco etc additional caulking may be required Earth Ground the Green Yellow wire using the provided wire nut Black Green White Black Green White To Wiegand Input on K 1700 IP Connect to Ground on En...

Страница 6: ...Hub Available LAN with PoE class 2 6 5 watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM PC Programming Download and install the programmi...

Страница 7: ...ng you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the n...

Страница 8: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 9: ...cting an integer 1 to 4094 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to h...

Страница 10: ...ash slowly for 3 seconds 2 beeps fast flash for 6 seconds 4 beeps then light steady indicating when to release button Step 4 You can now enter programming by following the steps in section B Step 1 Po...

Страница 11: ...d factory set to ON 23 18 Speaker Volume 0 9 factory set to 3 24 18 Ring Volume 0 9 factory set to 5 25 18 Microphone Volume 0 9 0 Auto factory set to 5 26 18 In Band Audio Call Progress Enabled Disab...

Страница 12: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1700 IP Series Phone being programmed When registered to a...

Страница 13: ...ociated with that Speed Dial Number If there is no answer or a busy signal is detected the K 1700 IP will then dial the Roll Over Phone Number The Primary Phone Number programmed in Index 0 is the num...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...the ability to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call...

Страница 16: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Страница 17: ...second relay activation time is recommended Alarm Mode When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered to the SIP server In the event...

Страница 18: ...l truck Factory Setting 5 seconds 26 Microphone Volume Automatic Noise Cancelling Mode This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Delay can be...

Страница 19: ...SIP calls One option is to generate a loud ring sound through the speaker The K 1700 IP Phone can also auto answer a SIP call to transmit a page control the relay or listen to transmit audio from the...

Страница 20: ...he gateway The three beeps can be muted by clicking on Mute Current Next Alarm The Status LED will continue to flash to assist troubleshooting The alarm beeps can also be permanently disabled See Perm...

Страница 21: ...ically only used when Viking Technical Support has sent you updated firmware 43 Import Export The Import Export feature is useful for backing up all the K 1700 IP s programming or for importing progra...

Страница 22: ...nd Toggle To use a keyless entry code the tenant simply dials followed by the entry code on the K 1700 IP s keypad These can be entered before or after pressing the call button After the one time use...

Страница 23: ...nectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc...

Страница 24: ...x7 SS VE 6x7 PNL VE 6x7 PNL SS VE 5x10 VE 5x10 SS VE 5x10 PNL VE 5x10 PNL SS VE 3x5 VE 5x10 NR VE 5x10 NR SS The VE GNP gooseneck pedestals are designed to be used with the VE 5x5 VE 6x7 and VE 5x10 b...

Страница 25: ...hich allow the reader to be conveniently adjusted and leveled To allow both indoor and outdoor operation the electronics are sealed in tamper resistant epoxy potting Concealing the mounting hardware t...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: