6
MAC:
18E80FXXXXXX
asdesaxtff
Rear (PCB) View of the
VoIP Tower Phone Panel
Important: Polarity Sensitive!
Black with White stripe
120V AC
12V DC
Adapter
(included)
(Positive)
Black
Connect to SL-2
Strobe Light
(included)
N.C. (Gray)
not connected
N.O. (Yellow)
COM. (Blue)
Gel-Filled Butt
Connectors (included)
Green
(see section A
below)
Red (+)
Black (-)
(Negative)
Wiring
IMPORTANT:
Electronic devices are susceptible
to lightning and power station electrical surges
from both the AC outlet and the telephone line. It
is recommended that a surge protector be
installed to protect against such surges.
The
SL-2
can be user programmed as a Beacon only, Strobe only or Beacon/Strobe. The brightness setting can be
programmed separately for the Strobe or Beacon and one of 4 different Flash Patterns can be programmed for the strobe
(see
Strobe Flash Patterns
, on page 7).
Note
:
The
SL-2
is factory default programmed as a steady on beacon with a
single flash strobe when activated. The beacon and strobe are set to their brightest settings. All programming should be
done prior to connecting to the 2 amp relay contacts on the
1600-IP
PCB.
(Optional, the
SL-2
is factory programmed to the Beacon/Strobe Mode and brightest Beacon/Strobe settings).
Step 1.
Apply 10-15 VDC power to the Red (+) and Black (-) wires.
Step 2.
Touch and hold the Green (Control) wire to the Black (-) wire for 3 seconds. The strobe should flash twice.
You are now in Programming mode.
Note:
Once in the programming mode, if a programming command
has not been entered for 20 seconds the strobe will flash 3 times indicating the unit has exited programming
and returned to the Run Mode.
Programming the SL-2 Stobe / Beacon
A. Accessing the Programming Mode