background image

2

Viking VoIP SIP System Compatibility List

NOTE:

Exclusion from this list means only that compatibility has not been verified,

it does not mean incompatibility

.

For detailed configuration instructions for certain vendors below, see 

Configuring Viking VoIP Phone and SIP

Servers

,

DOD 944

.

* Note: 

Relay operation commands are Not compatible with Panasonic Phone Systems (Panasonic does not transmit DTMF between station ports).

On-Premise

More information

available, see

DOD 944

3COM VCX

3CX

Allwork

4

Aastra

Asterisk

Atcom

Avaya Aura Platform V6.2.9 or earlier

Avaya IP Office Platform

BlueBox

Brekeke

Cisco Unified Communications
Manager (CUCM)

Cisco Unified Communications
    Manager Express (CUCME)

Elastix

epygi QX200

4

Freeswitch

Grandstream

4

Interactive Intelligence

iPECS (Ericsson-LG)

4

Iwatsu ECS

4

Kamailio

Mitel 3000

NEC

OfficeSIP

OpenSIPS

Panasonic* (with SIP Extension Card)

PolyCom (SIP paging only)

Samsung Communications Manager
(SCM)

ShoreTel

4

Siemens Communications Server (SCS)

SIP Express Router (SER)

Snom PBX

Sonus

Switchvox

Teksip

Toshiba

Vertical Wave

4

Yealink T Series S      IP Phones

Cloud Based Service Provider

More information

available, see

DOD 944

Callcentric

4

iptel.org

MetaSwitch

Ring Central

sip.antisip.com

Switchvox

unify

Vertical Wave

4

Voice Carrier

VoIP.MS

4

Содержание E-1600-ASTIPEWP

Страница 1: ...P ADA Compliant VoIP Emergency Tower Phones are designed to provide quick and reliable handsfree communication for SIP VoIP phone systems with PoE The tower phones meet ADA requirements for emergency...

Страница 2: ...6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstream 4 In...

Страница 3: ...ransport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A...

Страница 4: ...aceplate Marine grade 316 stainless steel Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Mounting Screws 4 T 10 Torx head stainless steel flat...

Страница 5: ...be Panel Attention To make sure water drain notch between stobe and panel is facing down attach strobe panel with wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above th...

Страница 6: ...one of 4 different Flash Patterns can be programmed for the strobe see Strobe Flash Patterns on page 7 Note The SL 2 is factory default programmed as a steady on beacon with a single flash strobe when...

Страница 7: ...g through 6 different beacon brightness settings from lowest to highest When the SL 2 lights at the desired beacon brightness level immediately remove the Green wire from the Black The SL 2 should fla...

Страница 8: ...ions of Windows Adobe Acrobat Reader 8 or higher VoIP Tower Phone hardware Available LAN with PoE class 1 4 Watts Ethernet cable CAT5 min 1 MB minimum free hard drive space for installation 16MB of fr...

Страница 9: ...g you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the ne...

Страница 10: ...ogramming settings Step 5 Click on the IP Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to...

Страница 11: ...ting the LAN Cable RJ45 plug Step 2 Press and hold the call button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Call button until you hear 2 beeps approximately 6 seconds Then releas...

Страница 12: ...16 Microphone Volume 0 9 0 Auto factory set to 5 23 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 17 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 17...

Страница 13: ...the Register Fails drop down box NOTE The maximum length of the SIP server address is 75 characters 6 Register Fails Re Resolve or Alternate Server 4 Outbound Proxy If your SIP provider requires an ou...

Страница 14: ...or stereo 2 Sampling rates of 8k 16k or 32kHz are acceptable 3 The WAV file may be stereo or multi channel but only the Left Channel will be loaded 4 When saved wave files will be converted to 8KHz m...

Страница 15: ...o or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate...

Страница 16: ...essing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 19 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The E 160...

Страница 17: ...wer limit or touch tone to hang up Factory Setting 3 minutes 29 Call Length Timeout This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Delay can be pr...

Страница 18: ...re options for auto answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound...

Страница 19: ...ferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the LED will not light during normal operation It will only light blink if it cannot register w...

Страница 20: ...rm 39 IP Firmware If new VoIP Tower Phone firmware is available after opening the programming software a pop window will come up asking you if you would like to update firmware An alternative method o...

Страница 21: ...l know the location of the emergency call by either the voice announcement or by decoding the touch tone I D number Once the Call Connected LED is on the key can be used to force the phone to hang up...

Страница 22: ...uncement to identify the location of the emergency call Alternatively a DTMF Touch Tone code may also be delivered A Call Connected LED can be initiated manually or automatically All programming param...

Страница 23: ...s products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any tim...

Отзывы: