0478 131 9937 B - EN
12.1 Planning routing of the perimeter
wire
●
Determine the
location of the docking
zone
●
Either remove
obstacles
from the
mowing area, or include no-go
areas. (
●
Perimeter wire:
The perimeter wire must be routed in a
continuous loop around the entire
mowing area.
Maximum length:
500 m
Minimum length:
70 m
●
Corridors and secondary areas
:
For automatic mowing, join all parts of
the mowing area by means of
corridors
. (
If there is insufficient space to do so,
secondary areas
must be
installed. (
●
Observe the specified
clearances
when routing the perimeter wire:
for obstacles that can be travelled on
(e.g. paths):
0 cm
for corridors:
80 cm
for high obstacles (e.g. walls, trees):
27 cm
minimum wire clearance in confined
areas:
80 cm
for water features and potential sudden
drops (edges, steps):
100 cm
●
Corners
:
Avoid routing at acute angles (less than
90°).
●
Guide loops
:
If offset drive home (passage) is to be
used, guide loops must be
installed. (
●
Reserve wire
:
Reserve wire should be installed at
several points to make it easier to
subsequently change the routing of the
perimeter wire. (
12.2 Making a sketch of the
mowing area
During installation of the robotic
mower and the docking zone, it is
recommendable to make a sketch of the
mowing area. A page has been provided at
the start of this instruction manual for this
purpose.
The sketch should be modified in the event
of subsequent changes.
Content of the sketch:
–
Contour of the mowing area
including
important obstacles, borders and any
no-go areas which the robotic mower
must not mow. (
– Position of the
docking zone
– Position of
perimeter wire
After a short while, the perimeter wire is
overgrown and is no longer visible.
Make a note of the routing of the wire
around obstacles in particular. (
– Position of the
wire connectors
After a short while, the wire connectors
used are no longer visible. Their
position should be noted in order to
replace them as required. (
12.3 Routing the perimeter wire
●
Study the
installation examples
at
the end of this instruction
manual. (
Include no-go areas, corridors,
secondary areas, guide loops and
reserve wire during routing of the
perimeter wire, in order to prevent
subsequent corrections.
For mowing areas < 40 m² and only
when the red LED on the docking
station signals SOS, the accessory
AKM 100
must be installed
together with the perimeter wire.
Coiled up residual pieces of
perimeter wire can cause
malfunctions and must be removed.
1
Only use original fixing pins and
original perimeter wire.
Installation
kits
with the necessary installation
material are available as an
accessory from the specialist
dealer. (
The routing direction (clockwise or
counterclockwise) is freely
selectable according to
requirements.
Never pull out fixing pins using the
perimeter wire – always use a
suitable tool (e.g. universal pliers).
Make a sketch of the perimeter wire
routing. (