0478 131 9937 B - EN
116
Fix the master docking station (B) into
position at the chosen location using four
pegs (H).
●
Install the power supply unit outside the
mowing area, protected from direct
sunlight, humidity and moisture – fasten
to a wall if necessary.
●
Route all power cables outside the
mowing area, in particular out of reach
of the mowing blade, and fasten them to
the ground or accommodate in a cable
duct.
●
Unreel power cables in the vicinity of
the docking station in order to avoid
interference with the wire signal.
●
Connect the mains plug.
●
After completing this installation
work, press the OK button on the
control panel.
Lift the robotic mower slightly by the
carrying handle (1) to relieve the weight on
the drive wheels. Push the machine,
resting on its front wheels, into the master
docking station.
The LED on the master docking station
flashes slowly after docking. (
Then press the OK button on the
control panel.
9.11 Routing the perimeter wire
Correct operation of the power
supply unit is only ensured at an
ambient temperature
between
0° C
and
40° C
.
The LED indicator on the master
docking station flashes. (
Please read and observe the entire
"Perimeter wire" section before
performing wire routing. (
In particular,
plan
the routing,
observe the
wire clearances
and
install
no-go areas
,
reserve wire
,
linking sections
,
secondary
areas
and
corridors
during wire
routing.
For mowing areas < 40 m² and only
when the red LED on the docking
station signals SOS, the accessory
AKM 100
must be installed
together with the perimeter wire.