VIKING TECHNICAL SUPPORT 1.800.908.0884
3 8
TROUBLESHOOTING
LCD Display References
LCD MSG
Meaning
Page 40
TS Ref #s
Error Messages
Er PANEL
LOW
Indicates that the voltage being provided from the Solar Panel is too low.
1, ?
ER PANEL
HIGH
Indicates that the voltage being provided from the Polar Panel is too High.
1, ?
ER SOLAR
NO PANEL
Indicates that there is no voltage being provided from the Solar Panel
1, ?
ERR CHRG
HIGH
Potential problem with the Solar Charger.
1, 2, ?
ERR BAT
LOW
The voltage from the Battery is low.
1, 2, 3,
?
ERR FUSE
15 AMP
15 Amp motor fuse is blown.
7, 11, 12
ERR ___
LIMIT
Indicates that the open
“OPN”
, close
“CLS“
or both
“NO“
limits are cleared
and need to be set.
23
ERR REFV
WRONG
One, or more, of the Control Board internal reference voltages are
incorrect.
?
ERR SENS
UL RO
There is a problem with the required monitored sensor(s) connected
to the “UL” and/or “Re-Open” input terminals (pg 6-7, 19).
20