background image

23

SHOWER ENCLOSURE LIMITED LIFETIME WARRANTY

EFFECTIVE JANUARY 1, 2010

only to the original owner or end-user for personal household use. For commercial uses, additional limitations apply.

VIGO warrants the structural glass component of the Product to be free from defects in workmanship and materials under normal use and service for the

period commencing from the initial date of purchase by the owner or end-user, contractor, or builder, from VIGO or an authorized VIGO dealer, through

the lifetime of the original owner or end-user.

VIGO warrants the hardware components of the Product to be free from defects in workmanship and materials under normal use and service for a period
of two (2) years from the initial date of purchase by the owner or end-user, contractor, or builder, from VIGO or an authorized VIGO dealer.

VIGO warrants the seal strip components of the Product to be free from defects in workmanship and materials under normal use and service for a period
of one (1) year from the initial date of purchase by the owner or end-user, contractor, or builder, from VIGO or an authorized VIGO dealer.

Subject to the Warranty Service provision below, any product reported to the authorized dealer or to VIGO as being defective within the warranty period
will be repaired or replaced (with a product of equal value) at the option of VIGO. This warranty extends to the original owner or end-user and is not
transferable to a subsequent owner.

Neither the distributor, authorized VIGO dealer, nor any other person has been authorized to make any affirmation, representation, or warranty other than

those contained in this warranty.  Any affirmation, representation, or warranty other than those contained in this warranty shall not be enforceable against
VIGO or any other person.

VIGO reserves the right to modify this warranty at any time, it being understood that such modifications will not alter the warranty conditions applicable at
the time of sale of the products in question.

Limitations

This warranty shall not apply to instances of incorrect operating procedures, breakages, or damages caused by fault through improper installation,
carelessness, abuse, misuse, misapplication, improper maintenance, or alteration of the Product, as well as chemical or natural corrosion, accident, fire,
flood, an act of God, or any other casualty. Avoid abrasive cleaners, steel wools, and harsh chemicals as these will scratch, damage, and / or dull the

product and / or finish and void this warranty.  The owner/end-user of the Product covered by the present warranty is entirely responsible for its proper
installation and any applicable plumbing or electrical wiring. VIGO neither installs nor supervises the installation nor hires a contractor for this purpose;
consequently, VIGO cannot be held responsible for any default, breakage, or damages caused thereby or resulting thereof, either directly or indirectly.

The owner/end-user must provide access to the components of the Product as described in the installation guide so that VIGO can execute the warranty
specified herein.  If such access is not available, all expenses to provide said access will be the responsibility of the owner/end-user.

This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable

rules, regulations, and legislation pertaining to such installations.

This warranty does not apply unless the VIGO Product is installed by fully insured licensed professionals.  Vigo strongly recommends that such licensed

professionals have experience in the installation of bathroom and kitchen products. Installation of certain products, including, without limitation, glass
products (i.e., shower doors and glass sinks) by an inexperienced person may result in glass breakage and, consequently, cause personal injury or
death.

VIGO is not liable for personal injuries or deaths to any persons or for any direct, special, incidental, or consequential damage, loss of time, loss of profits,

inconvenience, incidental expenses, labor or material charges, or any other costs resulting from the use of the product or equipment or pertaining to the
application of the present warranty, or resulting from the removal or replacement of any product or element or part covered by this warranty.

EXCEPT AS OTHERWISE PROVIDED ABOVE, VIGO MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR COMPLIANCE WITH ANY CODE.

In any case, VIGO cannot be held liable for any amount over and above the purchase price paid for the Product by the owner/end-user, contractor, or
builder.

Commercial Limitations
In addition to the above conditions and limitations, the warranty period for products installed for commercial applications or used in commercial ventures
is one (1) year from the initial date of purchase by the owner/end-user, contractor, or builder from an authorized dealer. VIGO is not responsible for loss of
use or profit under any circumstances. If the product is used as a display, the warranty period begins when the product is placed on display.  This
warranty gives the owner/end-user specific legal rights. The owner/end-user may also have other rights which can vary from one state or province to
another.

Warranty Service

In order to obtain service provided under this warranty during regular business hours, contact the dealer or distributor who sold the unit, or contact VIGO

directly. VIGO will provide the warranty service described above when the following conditions have been met: the failure is of the nature or type covered

during the warranty period; conclusive evidence (e.g., proof of purchase or installation) is provided to the foregoing by the user proving that the failure
occurred or was discovered within the warranty period; an authorized independent service person or company representative has been permitted to

inspect the product during regular business hours within a reasonable time after the problem was reported by the user.  VIGOs warranty obligation shall

*Certain models are pending approval.
Certification may be ended by VIGO or certification agencies without notice.

MODEL VG06045

Содержание VG06045 Series

Страница 1: ...lation of the product These instructions must be observed for safe installation Maintenance and other important non personal injury and non material damage instructions or statements that should be observed It is highly advised to dry fit the unit prior to any installation IMPORTANT SAFETY PRECAUTIONS WARNING 1 VIGO reserves the right to modify update all hardware and glass components based on bet...

Страница 2: ...Strip 1pc 1 extra 12 Glass Supports 2pc 13 Hex Screw 1 5 8 6pc 14 Phillips Screw 3 4 1pc 15 Green Plastic Anchor 1pc 16 White Plastic Anchor 6pc 17 Hex Screw Cover 15pc 18 Allen Key Pack 1 pack 19 Door Seal Strip 2pc 1 extra 2 NOTE INSTALLATION MUST BE DONE BY A QUALIFIED LICENSED PROFESSIONAL 1 1 2 1 10 16 12 13 4 16 12 13 1 8 6 1A 1A 9 7 3 3 1A 11 GLASS THICKNESS 10mm 13 13 16 16 16 13 16 1A 5 1...

Страница 3: ...84 62 98084 64 ALLEN KEY PACK 18 MISC DIMENSION B FIXED PANEL DIMENSION A DOOR 26 1 2 x 71 1 2 23 3 8 x 72 3 4 HEIGHT 72 3 4 MODEL VG06045XX4873 ADJUSTABLE DIMENSION C WIDTH 46 48 27 1 2 x 71 1 2 24 3 8 x 72 3 4 VG06045XX5073 48 50 32 1 2 x 71 1 2 29 3 8 x 72 3 4 VG06045XX6073 58 60 33 1 2 x 71 1 2 30 3 8 x 72 3 4 VG06045XX6273 60 62 34 1 2 x 71 1 2 31 3 8 x 72 3 4 VG06045XX6473 62 64 72 3 4 72 3 ...

Страница 4: ...DIAGRAM BELOW INSTALLATION OF THE SHOWER DOORS BY AN INEXPERIENCED PERSON MAY RESULT IN GLASS BREAKAGE AND CONSEQUENTLY CAUSE PERSONAL INJURY OR DEATH Handle fragile items with care to prevent personal injury or material damage The glass panels are tempered and cannot be cut Never attempt to do so Always rest glass on a level surface BEFORE STARTING Compare items on your invoice with what you have...

Страница 5: ...n and may vary depending on the site requirements To prevent damage to the finish you should protect the shower cabin bottom with a cardboard protector before beginning the installation Ensure that there is sufficient structural support behind the shower wall to hold the weight of the shower door If there is insufficient enough support then reinforce the shower walls with wooden studs prior to sho...

Страница 6: ...on Note that part 9 is reversible based off the configuration desired This is also the only side of the rail that can be cut Dry fit all steps prior to installation 1 Ensure that the bottom wall mount brackets 1A are on both ends of the bottom structural rail 9 Place the structural rail into the fixed panel holder 7 opening If the structural rail is too long cut it with a hacksaw until it fits the...

Страница 7: ...rk the location of the fixed panel holder 7 on the floor using the arrow marker on the structural rail as a guide 3 Remove the structural rail and fixed panel holder Drill holes into the respective marks and insert plastic anchors 16 inside them Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily h...

Страница 8: ...install the fixed panel seal strip 10 on the fixed panel 4 when checking for accurate dimensions Attach the seal strip 10 to the wall side of the front fixed panel 4 Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass 5 Install the mounting clips from 1A using hex screws 13 making sure that both sides are level Replace the bottom struc...

Страница 9: ...de it back as far as possible from the glass before you tighten The part that connects to the wall should be facing in Be sure to use washers on both sides of the panel WASHERS 12 4 12 10 VIEW FROM THE OUTSIDE VIEW FROM THE SIDE FIXED PANEL HOLDER 7 CAP FIXED PANEL 4 GASKET B2 1A 17 A6 5 Install the hex screw covers 17 to the bottom wall mount brackets 1A If this is not done now the installation o...

Страница 10: ...th the center point of the fixed panel holder 7 the fixed panel 4 and the bottom structural rail 9 should be parallel prior to attaching the fixed panel to the wall 4 Remove the front fixed panel Drill holes into the respective marks and insert plastic anchors 16 inside them Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causin...

Страница 11: ... PANEL 4 HEX SCREW 5 Screw the fixed panel to the wall with the with 1 5 8 screws 13 6 Replace the fixed panel holder face plate cap to the fixed panel holder by screwing the cap back on from the other side of the glass B5 16 13 4 7 4 VIEW FROM THE OUTSIDE CAP B6 4 ...

Страница 12: ...ening 2 Position the top roller guide 2 onto the fixed panel Position the structural rail correctly using a level Mark the location of the wall mount brackets 1 on the wall The height of the center of the wall mount brackets should be 73 1 4 NOTE The measurement of 73 1 4 should just be used as a guide Your actual dimension may vary C1 C INSTALLING THE TOP STRUCTURAL RAIL 2 1 8 1 4 C2 TOP ROLLER G...

Страница 13: ...13 Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily harm Note The housing to the top wall mount bracket assembly 1 will need to be unthreaded in order to install the mounting clips 4 Replace the structural rail and slide mounting brackets against the wall Tighten the hex screws NOTE There is a 1...

Страница 14: ...s at the bottom of the door panel 5 Fully tighten the screws and re install the roller cover Repeat steps 1 and 2 for the other roller 3 Cut the door bottom seal strips 11 according to the chart on the following page to accommodate the configuration and size of your unit Install the door bottom seal strips 11 onto the bottom of the door panel 14 MODEL VG06045 D1 D2 D3 ROLLER 3 ROLLER HEIGHT ADJUST...

Страница 15: ... 3 4 14 9 16 3 3 8 3 3 8 4 1 8 RIGHT DOOR INSTALLATION LEFT DOOR INSTALLATION 48X74 50X74 60X74 62X74 64X74 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 MODEL SIZE ...

Страница 16: ...ses to the wall Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass 5 The door seal strips must all meet each other properly to avoid any leakage Please note that seal strip 19 will be installed in Step E D4 D5 10 11 19 10 11 5 11 5 19 ...

Страница 17: ...lls that are not 100 plumb The bottom screw on the face of the roller adjusts the height of the ball bearing inside You may need to remove door unit from install to modify height It will also require two people One person to hold the glass in the closed position while the other loosens the roller height adjustment screw and tightens when the glass is in the desired position Please refer to pages 2...

Страница 18: ...E HANDLE 1 Unscrew the handle holders from the handle assembly 6 2 Install the handle as shown Make sure to have gaskets between any metal and glass F1 F2 E INSTALLING THE WATER SEAL STRIP 1 Attach the door seal strip 19 to the door and to the fixed panel respectively Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass E1 This end must...

Страница 19: ...en the floor and the fixed front panel G1 H1 H INSTALLING COVERS 1 Install screw covers 17 to the unit 2 If you haven t already done so install the roller covers There is no need to install silicone between the roller cover and the roller Applying silicone here will not allow for future height modification ROLLER 3 ROLLER HEIGHT ADJUSTMENT SCREW ROLLER COVER 1A 17 1 17 H2 ...

Страница 20: ...to remove IMPORTANT 1 DO NOT use abrasive cleaners scrapers metal brushes or any items that could scratch or dull the surface 2 DO NOT allow surface to come in contact with acetone nail polish remover dry cleaning solution lacquer thinner gasoline or other similar products REGULAR CARE AND MAINTENANCE OF YOUR VIGO SHOWER ENCLOSURE Your home is a moving entity shifting and settling over time Vigo u...

Страница 21: ...e rollers should be adjusted as shown in Fig 4 FIG 1A IMPORTANT NOTE These adjustments are approximate You may need to adjust the roller height adjustment screw to meet your needs NOTE There is an adjustment on the roller to accommodate walls that are not 100 plumb The bottom screw on the face of the roller adjusts the height of the ball bearing inside Loosen this screw adjust to desired closed do...

Страница 22: ...he highest position A B The roller height adjustment screw is in the highest position The roller height adjustment screw is in the lowest position 22 MODEL VG06045 STRAIGHT WALLS TOP ANGLED WALL FIG 3 FIG 2 BOTTOM ANGLED WALL ROLLER A ROLLER HEIGHT ADJUSTMENT SCREW ROLLER B ROLLER HEIGHT ADJUSTMENT SCREW WALL DIRECTION BOTTOM ANGLED FIG 4 HIGHEST LOWEST ROLLER A ROLLER HEIGHT ADJUSTMENT SCREW ROLL...

Страница 23: ...lation guide so that VIGO can execute the warranty specified herein If such access is not available all expenses to provide said access will be the responsibility of the owner end user This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installation...

Отзывы: