TOP ROLLER
GUIDE (2)
FIXED PANEL (4)
OUTSIDE OF
SHOWER
INSIDE OF
SHOWER
8
DOOR
PANEL (5)
HEX SCREWS
17
MODEL VG06045
D6
6. Position the door on top of the bottom
structural rail (#9) making sure the rollers
(#3) are straddling the rail. Slide the top
roller guide (#2) along the fixed panel closer
to the door so that the door panel slides into
the opening. Once the top roller guide (#2)
is in the correct position with the fixed panel
(#4) and the door panel (#5) both in place,
tighten the hex screws to keep in place.
7. Note that there is an adjustment on the roller
to accommodate walls that are not 100%
plumb. The bottom screw on the face of the
roller adjusts the height of the ball bearing
inside. You may need to remove door unit
from install to modify height. It will also
require two people. One person to hold the
glass in the closed position while the other
loosens the roller height adjustment screw
and tightens when the glass is in the desired
position. Please refer to pages 21-22 for
Roller Adjustments to Accommodate Out of
Square Openings
. Once the rollers are
properly adjusted and the door sits flush
against the wall in the closed position, the
adjustment will be complete. Fully tighten
the adjustment screws and re-install the
roller covers.
2
5
4
8
9
3
3
D7
ROLLER (3)
ROLLER HEIGHT
ADJUSTMENT SCREW
ROLLER COVER
LOOSEN THESE
3 SCREWS