![Viessmann VITOVENT 300 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/viessmann/vitovent-300/vitovent-300_service-instructions-for-contractors_1017789015.webp)
Slider aperture width
A
[mm]
Actual air velo-
city [m/s]
10
15
20
Air flow rate [m
3
/h]
1.26
1.89
2.52
0.1
2.62
3.78
5.04
0.2
3.78
5.87
7.56
0.3
5.04
7.56
10.08
0.4
6.30
9.45
12.60
0.5
7.56
11.34
15.12
0.6
8.82
13.23
17.64
0.7
10.08
15.12
20.16
0.8
11.34
17.01
22.88
0.9
12.80
18.90
25.20
1.0
13.86
20.79
27.72
1.1
15.12
22.88
30.24
1.2
16.38
24.57
32.76
1.3
17.64
26.46
36.28
1.4
18.90
28.36
37.80
1.5
Slotted outlet (ventilation air element for wall and ceiling mounting)
Flow rate up to 35 m
3
/h
A
Slot width
1.
Determine the width of the air inlet
using the intended flow rate and the
specified pressure drop from the
following diagram.
Further details regarding the individual steps