19
A
B
Fig. 15
1.
Check the wire mesh and cover of burner gauze
assembly
A
for damage. Slight wavy deforma-
tions in burner gauze assembly
A
are not prob-
lematic.
2.
Replace burner gauze assembly
A
if required.
3.
Check seal
B
between the burner gauze assem-
bly and thermal insulation. If required, replace seal
B
.
Checking the ignition and ionisation electrodes
Ignition electrodes
8.5
1±
Fig. 16
7
1.5+
6
1
±
Fig. 17
Ionisation electrode
15.5
1±
Fig. 18
Check the ignition electrodes and ionisation electrode
for the correct gap to the burner gauze assembly and
for possible damage. Replace the electrodes if
required.
Cleaning the burner
B
C
E
D
A
F
Fig. 19
1.
Undo fitting
C
on gas supply pipe
B
.
2.
Undo Venturi mixing pipe
D
from fan
E
.
3.
Remove Venturi mixing pipe
D
with gas train
A
and gas supply pipe
B
. Disconnect the connecting
cables.
Commissioning, inspection, maintenance
Checking the burner gauze assembly
(cont.)
5783 337 GB