102
6167 818 - 10
Vitodens 100-W, B1HE/B1KE Combi Installation/Service
Boiler Model No.
B1KE-120
B1KE-199
Max. Input NG and LPG
(DHW production only)
MBH
kW
140
41.0
199
58.3
Max. boiler temperature
(during DHW production)
ºF (ºC)
194 (90)
194 (90)
DHW supply temperature
ºF (ºC)
140 (60)
140 (60)
Continuous draw rate *
1
at
t= 77ºF (43K)
USG/min.
(L/h)
3.3
757
4.7
1070
Max. flow through heat exchanger
USG/min.
(L/h)
3.7
(840)
5.3
(1200)
Maximum allowable working pressure
(potable water)
psi
150
150
Test pressure
psi
300
300
*
1
DCW and DHW temperature rise would be proportional. Maximum DHW supply temperature is 140ºF (60ºC).