66
6167 818 - 10
Vitodens 100-W, B1HE/B1KE Combi Installation/Service
DHW
(continued)
System Configuration (parameters)
534.0 “Circulation pump run-on”
Setting
Explanations
120 s
120
0 to 900
Circulation pump run-on after storage tank heating
Factory setting 120 sec run-on
Run-on time adjustable from 0 to 900 sec in 60 sec increments
(the run-on time is rounded down to full minutes)
Note:
To avoid damaging the boiler, do not set the run on time to < 120 sec.
1085.0 “Tank heating: Start point target”
Setting
Explanations
25
10 to 100
Start point for DHW heating below target DHW temperature
Factory-set start point 2.5 K (5°F) below target DHW temperature
Adjustable start points:
10: 1.0 K (1.8°F)...
100: 10.0 K (18°F)
Note:
Parameter not valid for a DHW tank with temperature switch!
Irrespective of this, the stop point is 2.5 K (5°F) above the target DHW temperature.
1087.0 “Max. duration, DHW heating”
Setting
Explanations
60
0
1 to 240
After a set period of time has elapsed, DHW heating ends even though the target
DHW temperature has not yet been reached.
Not adjustable on gas condensing combi boilers
Factory setting 60 min
No time limit for DHW heating
Duration of DHW heating adjustable from 1 to 240 min in 1 min increments
1087.1 “Min. delay until next time DHW is heated”
Setting
Explanations
60
60 to 240
Minimum delay before DHW heating starts again after the maximum duration from
1087.0 has been exceeded, even though there is a demand.
Not adjustable on gas condensing combi boilers
Factory setting, delay of 60 min
Delay adjustable from 60 to 240 min in 1 min increments
1101.2 “Set speed of the primary circuit pump for DHW heating”
Setting
Explanations
...
Target speed of the internal circulation pump when operated as a DHW pump
Factory settings defined by settings specific to the boiler
The setting range depends on the boiler
Содержание B1HE Series
Страница 97: ...97 6167 818 10Vitodens 100 W B1HE B1KE Combi Installation Service B1HE Models 85 120 150 199 Wiring Diagram ...
Страница 98: ...98 6167 818 10 Vitodens 100 W B1HE B1KE Combi Installation Service B1KE Models 120 199 Wiring Diagram ...
Страница 126: ...126 6167 818 10 Vitodens 100 W B1HE B1KE Combi Installation Service ...
Страница 127: ...127 6167 818 10Vitodens 100 W B1HE B1KE Combi Installation Service ...