95
!
Please note
Identify sensor leads.
Fasten sensor leads and disman-
tled leads (with plug
aS
/
aD
)
together with the other LV leads
using the cable ties provided.
Swimming pool heating
Note
■ Swimming pool heating is controlled
via external extension H1 with KM
BUS.
■ Make connections to external exten-
sion H1 only according to the following
diagram.
■ Connect only circulation pump for
swimming pool heating
F
to plug
gÖ
according to the following diagram. A
filter circuit pump must be connected
separately.
■ If the components for swimming pool
heating are connected to external
extension H1, no other external func-
tion (e.g. changeover of operating
mode) can be connected.
Installation sequence
Electrical connections
(cont.)
5609 667 GB
Installation