164
Internal hydraulics
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Heat pump for drying a building"
7300
0
"Time program for screed drying"
7303
0
"Set flow temperature for external de-
mand"
730C
500 (
≙
50 °C)
"Operating mode primary pump"
7320
Do not adjust
"Operating mode secondary pump"
7340
Do not adjust
Heating water buffer cylinder
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Enable buffer cylinder/low loss head-
er"
7200
0
"Temp. in operating status fixed value
for buffer cyl"
7202
500 (
≙
50 °C)
"Hysteresis temperature heating buf-
fer cylinder"
7203
50 (
≙
5 K)
"Max. temperature buffer cylinder"
7204
600 (
≙
60 °C)
"Temp. limit op. status fixed value for
buffer cylinder"
7208
100 (
≙
10 °C)
Heating circuit 1
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Standard room temperature"
2000
200 (
≙
20 °C)
"Reduced room temperature"
2001
160 (
≙
16 °C)
"Remote control"
2003
0
"Heating curve level"
2006
0 (
≙
0 K)
"Heating curve slope"
2007
6 (
≙
0.6)
"Influence room temperature hook-
up"
200 A 10
"Room temperature hook-up"
200 B 3
"Max. flow temperature heating cir-
cuit"
200E
400 (
≙
40 °C)
"Room temperature in party mode"
2022
200 (
≙
20 °C)
Commissioning/service reports
Commissioning/service reports
(cont.)
5609 667 GB