This monitor is assigned with DIP setting instructions.
On Address setting page,select DIP Switcher Set Address setting mode fi rstly, then touch
icon, total 32 DIP codes will be displayed.
DIP Switcher Set Address
The DIP switches are used to set the user code for each monitor.Total 6 bits can be confi gured.
• Bit-1 to Bit-5 are used for user code setting. The value range is from 0 to 31, which have 32
different codes for 32 apartments.
• When multi monitors need to be installed in onep aartment, these monitors should use the
same user code, and the master/slave mode should be set on the monitor. (Details refer to
the section of
Setting Slave Monitor
)
• Bit-6 is bus line terminal switch, which shoulde bset to “ON” if the monitor is at the end of
bus line, otherwise be set to “OFF”.
SYSTEM CONFIGURATIONS
ON(1)
=
OFF(0)
=
ON
ON
ON
DIP
1
2
3
4
5
6
Bit state
Setting
Bit state
Setting
1 2 3 4 5
6
ON
DIP
1 2 3 4 5
6
ON
DIP
When monitor is not
at the end of bus line.
When monitor is at
the end of bus line.
Bit-6 switch setting
SYSTEM CONFIGURATIONS
Manual Input Address
It’s available to input the address manually for this monitor.
• Total 32 numbers to be set, from 00~31.
• When multi monitors need to be installed in one a
partment, these monitors should use the
same user code, and the master/slave mode should be set on the monitor. (Details refer to
the section of
Setting Slave Monitor
)
1.On Address setting page,select Manual Input Address setting mode, then touch
icon, a
keypad will be displayed.
2.Input the code by touching the digital number.
3.Touch “OK” key to save, code setting complete.
4. Touch “
“ key to exit.
Cursor
Switch the keypad
between alphabet
and numbers
Keypad type
abc- Alphabet keypad
123-Number keypad
Edit box
Delete the last character
Save setting
Exit current page
INSTALLER SETUP
123
_
00-31
Space key
Insert a space.
Move the cursor.
.
Setting user code
In the building system, you can configure up to 32 apartamens in the basic version
Each apartment must have a individual address from 00-31 and this address should be set on monitors
or uniphones. If there is more than one monitor in one apartment,
all monitors or uniphones have the same address. Set the first monitor in the MASTER, the remaining
monitors in the SLAVE1/2/3.
In willa system, you can install up to 13 indoor devices in the one house.
By addressing them as described below, you will get the function of an addressed intercom between
selected monitors in the system. You can also connect to monitors in the second house if you know
their address
One house: 00-12 (the first monitor must have the address 00)
Two house: 00-12 for first house (the first monitor must have address 0)
16-28 for the second house (the first monitor must have the address 16)
There are two setting modes for address setting,DIP switcher and manual input .
30
31