V-Tap ISDN BRI Manual EN v2.6 Dec 2018 © 2017-2018 Vidicode 29
•
Red LED steady ON
with “Button
Start/Stop
” function.
If manual recording with the button is enabled, then the Red
LED ON means that recording is active.
•
Red LED blinking plus Green LED blinking.
The system cannot connect to the Tunnel server.
See also
Green LED blinking
below.
•
Red LED blinking once per second.
This happens when you take out the SD card while the system
was still busy writing to it. So, an unclosed (0 bytes) file is now
on the card. For more information, see
Remove SD Card safely
.
•
Red LED blinking fast.
This indicates that the analog line is disconnected. It can only
happen when on/off-hook detection is selected for start/stop.
•
Red LED blinking fast,
together with all other LED’s.
This happens after a fatal error in the application. The firmware
must be updated.
4.2
Green Link LED
The Green LED is used to show the status of the link to the Tunnel server
or to show the recording state when the button start/stop mode is
configured without Tunnel. See also
Button setting
.
•
Green LED blinking.
The system tries to connect to the Tunnel server. This can last
forever, but normally it should take a few seconds after reset.
When longer, the Tunnel server could not be found, or the
network connection is bad. The Red LED also starts blinking in
that case. Check the firewall on the PC or switch!
The Green LED goes to steady ON when the connection is made.
•
Green LED steady ON.
The link to the Tunnel server is OK.
When start/stop with the button is selected and no Tunnel is
configured, it means that recording is active.