66250756-EN - V2.1 - 05/11/19
- 14 -
4000 Series GSM Lite Audio Intercom - Technical Manual
4000 Series GSM Lite Audio Intercom
Art. 4901 Technical Information
PROGRAMMING GUIDE
• Enter the
ENGINEER’S CODE
: first time type six times
1
(
111111
factory default) and press
ENTER
(the red LED will illuminate);
• Confirm
ENGINEER’S CODE
: re-type the same code again
or
type a new code (4 to 8 digits) then press
ENTER
(melody);
• Enter the code (4 to 8 digits) to enable
RELAY 1
then press
ENTER
(melody);
• Enter the
RELAY 1
operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press
ENTER
(melody);
• Enter the code (4 to 8 digits) to enable
RELAY 2
then press
ENTER
(melody);
• Enter the
RELAY 2
operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press
ENTER
(melody);
• Enter the code (4 to 8 digits) to enable
RELAY 3
then press
ENTER
(melody);
• Enter the
RELAY 3
operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press
ENTER
(melody);
• The system is ready to use (the red LED will switch OFF).
PROGRAMMING NOTES
• Pressing the
ENTER
button twice during the programming
process, without changing any parameters, will exit from the
programming menu.
• When entering a relay code it must be different from the
ENGINEER'S CODE
.
• To latch the relay type in the access code then press
ENTER
to confirm. To unlatch the relay type in the same access code
again then press
CLEAR
to confirm.
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
• Turn OFF the power to the codelock;
• Keep the
ENTER
button pressed while the power is turned
back ON;
• Release the
ENTER
button;
• The
ENGINEER’s CODE
is now reset back to 6x1 (
“111111”
).
ENTER THE
“ENGINEER’S CODE”
CONFIRM
OR CHANGE
“ENGINEER’S CODE”
ENTER
“ACCESS 1 CODE”
ENTER
“ACCESS 1 TIME”
ENTER
“ACCESS 2 CODE”
ENTER
“ACCESS 2 TIME”
SYSTEM
READY TO USE
ENTER
“ACCESS 3 CODE”
ENTER
“ACCESS 3 TIME”
Press
ENTER
(red LED
ON
)
Press
ENTER
(melody)
Press
ENTER
(melody)
Press
ENTER
(melody)
Press
ENTER
(melody)
Press 1 six times
“111111”
(factory default)
Press 1 six times
“111111” again
or
type new engineer’s
code (4 to 8 digits)
Type code to enable
relay 1 (4 to 8 digits)
Type code to enable
relay 2 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
red LED
OFF
Press
ENTER
(melody)
Type code to enable
relay 3 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Press
ENTER
(melody)
Press
ENTER
(melody)
TERMINAL CONNECTIONS
TECHNICAL SPECIFICATION
Connection
Description
Working voltage:
12V - 24Vac/dc +/- 10%
+
12-24V AC or DC power input
Current consumption:
20mA (standby); 70mA (max.)
-
0V power input
Number of relays:
3,
RLY1
,
RLY2
&
RLY3
(
C
,
NC
and
NO
)
C1
Relay 1 common connection
Rela
y c
o
ntac
ts:
3A @ 24V
ac⁄dc (max.)
Relay current ⁄ voltage:
3A @ 24Vac/dc (max.)
NO1
Relay 1 normally open connection
Push to exit inputs:
2,
SW1
and
SW2
(switched 0V)
NC1
Relay 1 normally closed connection
Back EMF protection:
Yes, 3x MOV jumpers
C2
Relay 2 common connection
Number of codes:
3 codes (1 code per relay)
NO2
Relay 2 normally open connection
Programming:
Via keypad
NC2
Relay 2 normally closed connection
Working Temperature:
-10 +50
o
C
C3
Relay 3 common connection
NO3
Relay 3 normally open connection
NC3
Relay 3 normally closed connection
SW1
Switched 0V PTE input to trigger relay 1
SW2