Jog Direction
[INVERSE/NORMAL]
Setting this to ‘Inverse’, the view in
the screen is moving the same
direction with jog, panning, and in
reverse with tilting.
If ‘Normal
’
is selected, the view in
the screen is moving in reverse of the
above: opposite direction panning,
and same direction tilting.
Freeze in
Preset
[ON/OFF]
Activates a function that holds the
image between preset selections,
eliminating the moving images.
As soon as camera stops at the
selected preset, the camera resumes
displaying live images at preset.
This function availability should be
different by models.
10.6.1.
Parking Action Setup
If Park Enable is set to ON, the camera runs an assigned
function automatically if there is no PTZ command
during assigned "Wait Time".
Park Enable
[ON/OFF]
Wait Time
[1 minute ~ 4 hour]
The time is displayed with
"hh:mm:ss" format and you can
change this in 1 min increments.
Park Action [HOME/PRESET/PATTERN/SWING/GROUP]
Camera is activated to selected function. If
there is no PTZ command during the
assigned "Wait Time".
Note: HOME position is Pan 0, Tilt 0, and
Zoom x1 – Position cannot be changed
10.6.2.
Alarm Input Setup
Match the Alarm sensor output type and select a preset.
If an external sensor is activated, camera will move to
this corresponding preset position.
Alarm × Type
[Normal OPEN/Normal CLOSE]
Sets sensor input type.
Alarm × Action
[NOT USED/PRESET 1~128]
Assign Preset position to each Alarm
input.
Doc # INS 20Z704T-PZ10
Issue Date: 08/13/2009
Revision: B
Page 29 of 40