8.7. Group
Function
The Group function allows running a sequence of Presets, Pattern
and/or Swings. Max 8 group can be stored. Each group can have a
max of 20 action entities, which can be preset, pattern or swing.
Preset speed can be set up and the repeat number of Pattern & Swing
in the Group setup. Dwell time between actions can be set up also.
Set Group
Use OSD Menu to create a Group.
Run Group
Method 1) <Run Pattern> [Group NO.+20]
ex) Run Group 7 : <Run Pattern> [27]
Method 2) <Go Preset> [Group NO.++150]
ex) Run Group 7 : <Go Preset> [157]
Delete Group
To delete Group, use OSD menu.
8.8. Other Functions
Power (Up Action) This function resumes the last action executed before power down.
Most actions, such as Preset, Pattern, Swing and Group, are available
for this function, but Jog actions are not available to resume.
Auto Flip
10x Zoom Model If the tilt angle arrives at the top of tilt orbit (90°
straight down), the images are reversed
automatically and F appears in screen. If this
function is set to OFF, tilt movement range is
limited to 0° ~ 95°.
Parking Action
This function enables the ability to locate the camera to a specific
position automatically. If the operator doesn’t operate the controller
for awhile, the Park Time can be defined as an interval from 1 minute
to 4 hours.
Alarm Input
4 Alarm Inputs are used. If an external sensor is activated, the camera
can be set to move to a corresponding preset position. It should be
noted that the last alarm input is in effect if multiple sensors are
activated.
Privacy Zone Mask To protect privacy, a maximum of 4 Privacy Masks can be created in
arbitrary position to hide objects such as windows, shops or a private
house. With Spherical Coordinates system, powerful Privacy Zone
Mask function is possible.
Doc # INS 20Z704T-PZ10
Issue Date: 08/13/2009
Revision: B
Page 20 of 40