7. Installation
7.1. DIP Switch Setup
Before you install the camera, you should set the DIP switches to configure the camera ID,
communication protocol.
7.1.1. Camera ID Setup
ID number of camera is set using dip switch. The example is shown bellow.
The range of ID is 1~255.
Do not use 0 as camera ID
. Factory default of Camera ID is 1.
If you want to control a certain camera, you must match the camera ID with Cam ID setting
of DVR or Controller.
7.1.2. Communication Protocol Setup
Select the appropriate Protocol with DIP switch combination.
Pin
1
2
3
4
5
6
7
8
ID Value
1
2
4
8
19
32
64
128
ex) ID=5
on off
on
off
off
off
off
off
ex)
ID=10 off on off on off off off off
Switch State
P0
(Pin 1)
P2
(Pin 2)
P3
(Pin 3)
Protocol
OFF OFF OFF PELCO-D,
2400
bps
ON
OFF
OFF
PELCO-D, 9600 bps
OFF
ON
OFF
PELCO-P, 4800 bps
ON
ON
OFF
PELCO-P, 9600 bps
Others Reserved
If you want to control using a DVR or P/T controller, their protocol must be identical to the
camera. Otherwise, you cannot control the camera.
If you changed camera protocol by changing DIP S/W, the change will be effective after you
reboot the camera.
Doc # INS 20Z704T-PZ10
Issue Date: 08/13/2009
Revision: B
Page 10 of 40