10
GVI Security
2.4 ID Setup
Change the analog Dome Camera’s ID if there is more than one Dome Camera in the same network. Use the
switch to change the PTZ Dome Camera’s ID by setting the 10-bit dip switch. For instance, if the camera’s ID
is 006, set the SW-2 and SW-3 to “ON,” with the rest to “OFF,” as shown below. For switch configuration
details, refer to Appendix B: Switch Settings Index Table.
NOTE:
To prevent communication conflicts, do not give the same ID to two Dome Cameras.
2.5 Camera Control Protocol Setup
Define the protocol based on the devices of the surveillance system. Use one protocol even if the devices are
provided from different manufacturers. Refer to the table below for the supported protocols with their
matching switch numbers and baud rate and choose a protocol for the camera. Refer to Appendix B.2:
Protocol Settings for further configuration details.
Switch
No.
Protocol
Baud
Rate
Switch Setting
SW-1
SW-2
SW-3
SW-4
SW-5
SW-6
00
VCL 9600
OFF
OFF
OFF
OFF
OFF
OFF
01
Pelco D
2400
ON
OFF
OFF
OFF
OFF
OFF
02
Pelco P
4800
OFF ON OFF OFF OFF OFF
04
Chiper
9600
OFF
OFF
ON
OFF
OFF
OFF
05
Philips 9600 ON OFF ON OFF OFF OFF
07
VideoPlus
9600
ON
ON
ON
OFF
OFF
OFF
08
AD422 4800
OFF
OFF
OFF
ON
OFF
OFF
09
DM P
9600
ON
OFF
OFF
ON
OFF
OFF
11
Pelco D
4800
ON
ON
OFF
ON
OFF
OFF
12
Pelco D
9600
OFF
OFF
ON
ON
OFF
OFF
13
Pelco P
2400
ON OFF ON ON OFF OFF
14
Pelco P
9600
OFF
ON
ON
ON
OFF
OFF
15
JVC 9600
ON ON ON ON OFF OFF
21
Kalatel-485
9600
ON
OFF
ON
OFF
ON
OFF
22
Kalatel-422 4800
OFF
ON
ON
OFF
ON
OFF
23
Panasonic
19200
ON
ON
ON
OFF
ON
OFF
*
31
Samsung 9600 ON ON ON ON ON OFF
Use the 6-bit dip switch (Camera Control Protocol Switch) to set the camera’s control protocol and its baud
rate. For example, if Pelco D is selected, (switch number one and baud rate 2400) then set the SW-1 to
“ON,” and the rest to “OFF” as shown in the example below.