45
!
Post-record
– to define how long after this alarm input is triggered the Focus
Camera shall be intensively recorded at Event Record IPS. Press
+/-
buttons to
adjust the value (0 second - 60 minutes, discrete).
!
Alarm Out
– to define which Alarm Output will be triggered when this alarm
input is triggered. Press
+/-
buttons to select none (N/A) or one of the Alarm
Outputs (NC (1), NO (2)).
!
Buzzer
– to activate the internal Buzzer or not when this alarm input is triggered.
Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
ˇ
” -
checked.
!
Log
– to log to event logs or not. Press
ENTER
or
+/-
to check/uncheck this
item. The default setting is “
ˇ
” - checked.
!
Screen Message
– to display the event message on the screen or not. Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
ˇ
” -
checked.
!
Notification
– to notify mobile phones and/or send the event e-mail to remote
station or not. The mobile phones with alarm notification from the DVR enabled
will be notified, and the e-mail will be sent to the predefined receivers when the
event is triggered. Press
ENTER
or
+/-
to check/uncheck this item. The
default setting is “
ˇ
” - checked.
!
FTP
– to send the recorded event video/audio files to FTP server or not. Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
–
” -
unchecked.