Multi RS Solar
48/6000
Protection (6)
a - g
Data Communications
VE.Direct port, VE.Can port & Bluetooth (7)
General purpose analog/digital in
port
Yes, 2x
Remote on-off
Yes
Operating temperature range
-40 to +65°C (fan assisted cooling)
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour
steel, blue RAL 5012
Protection category
IP21
Battery-connection
M8 bolts
PV Connection
2 positive & 2 negative MC4
230 V AC-connection
Screw terminals 13 mm² (6 AWG)
Weight
11 kg
Dimensions (hxwxd)
425 x 440 x 125 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, Immunity
EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
1) Can be adjusted to 60 Hz
2) MPPT operating range is also constrained by battery voltage - PV VOC should not exceed 8x battery float voltage. For
example, a 52,8V float voltage results in a maximum PV VOC of 422,4V. See product manual for further information.
3) A higher short circuit current may damage the controller if PV array is connected in reverse polarity.
4) The maximum charge current from the built in MPPT is 80A, to reach the 100A maximum charge current of the unit
requires additional AC PV connected.
5) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function, including
minimum closed time and relay-off delay. DC rating: 4A up to 35VDC and 1A up to 70VDC
6) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) Solar earth leakage
7) The Multi RS Solar is not currently compatible with VE.Smart Networks. Connection to a GX device (i.e. Cerbo GX) must
be made via the VE.Can interface. The VE.Direct interface is for connection to the GlobalLink 520.
Multi RS Solar
Page 38
Technical Specifications