4.11.6. User I/O terminal diagram
Figure 1.
User I/O Connector is located on bottom left side of connection area, diagram shows 3 perspectives. Left Side - Top - Right Side
4.11.7. User I/O functions
Table 3. User I/O Functions - See Installation Section for more details.
Number
Connection
Description
1
Relay_NO
Programmable relay Normally Open connection
2
AUX_IN -
Common negative for programmable auxiliary inputs
3
Programmable auxiliary input 1 positive connection
4
Programmable auxiliary input 2 positive connection
5
REMOTE_L
Remote on/off connector Low
6
REMOTE_H
Remote on/off connector High
7
RELAY_NC
Programmable relay Normally Closed connection
8
RELAY_COM
Programmable relay common negative
9
TSENSE -
Temperature Sensor negative
10
Temperature Sensor positive
11
VSENSE -
Voltage Sensor negative
12
Voltage Sensor positive
4.12. Programming with VictronConnect
This guide will help you with the specific elements of VictronConnect that relate to the MPPT Solar Charge Controller.
More general information about the VictonConnect App - how to install it; how to pair it with your device; and how to update
firmware, for example - can be found by referring to the overall
. A list of all VictronConnect compatible
.
Note: These instructions can apply to different products and configurations, where battery voltage is referred to in these
instructions, a 12V battery is used as a reference point. Please multiply the given values by 4 to arrive at settings for an
installation configured for the 48V battery system.