Battery, fill corresponds with voltage, blinks when empty
5.2. History - Thirty-day graphic
(The fragmented square icon (top left) allows you to toggle between 'portrait' and 'landscape' screen presentations.)
A summary of activity for the last 30 days is presented graphically. Swipe the bar left or right to show any of the previous 30 days.
The daily log shows:
•
Yield
: The energy converted for that day.
•
P max
: The maximum power recorded during the day.
•
V max
: The highest voltage from the PV array during the day.
Clicking on any day/bar in the graph will expand the information to show charge-status times - both as hrs/m; and also as a
percentage of the 'charge' day. This graphic provides an at-a-glance representation of how much time your charger is spending in
each of three modes: Bulk / Absorption / Float.
Tip! You can use the charge times to see if the PV array is properly sized for your requirements. A system which never reaches
'Float' may need more panels; or perhaps the load could be reduced?
It is possible to export the history as a comma separated file (.csv) by clicking the three connected dots at the top right of the
history screen: