Color Control GX manual
Victron Energy - https://www.victronenergy.com/live/
see 1.2.2 above for instructions.
1.2.6 VE.Can Resistive Tank Sender Adapter
See
its page and manual on our website
for details about the Adapter.
To connect a product with a VE.Can port, use a standard
RJ45 UTP cable
.
Don't forget to terminate the VE.Can network on both ends using a
VE.Can terminator
. A bag with two
terminators is supplied with each VE.Can product. They are also
available separately
(ASS030700000). (Available with straight or elbow connectors.)
Make sure that the canbus is powered, see the
Power chapter in the Tank Sender Adapter manual
for
details.
1.4.7 NMEA Tank senders from other manufacturers
A tank sender must meet the following requirements to be visible on the CCGX:
Transmit the NMEA2000 Fluid Level PGN, 127505
The NMEA2000 device class needs to be 'General', 80
The NMEA2000 function class needs to be 'Transducer', 190
For some tank senders it is also possible to configure the capacity and the fluid type from the CCGX -
for example the Maretron TLA100. This facility may be available with other senders made by other
manufacturers - it's well-worth trying.
To connect an NMEA2000 network to the VE.Can port on the CCGX, use a
VE.Can to NMEA2000 cable
.
Alternatively, instead of a VE.Can to NMEA200, you can use a 3802 cable from Oceanic Systems:
https://osukl.com/ve-can-adaptor/
. The difference is that it lends itself well to connecting a single
NMEA-2000 device into a VE.Can network. It's also able to power a lower voltage NMEA-2000 network
directly from a 48V Victron system.
1.5 Measuring PV Inverter output
Measuring the output of a PV Inverter will provide the user with an overview of both actual power
balance and the energy distribution. Note that these measurements are only used to display
information. They are not needed, nor used, by the installation.
There are several ways to show the output of a PV Inverter:
An AC Current Sensor
, wired to the analog inputs of a Multi or Quattro provides the information
1.
at the lowest cost - though it is the least accurate.
AC Current Sensor Manual
.
Fronius PV Inverters
can be read digitally via the local LAN. See the
CCGX / Fronius manual
.
2.
Using an
Energy Meter
, either wired to the CCGX, or connected wirelessly using our Zigbee to
3.
USB/RS485 interfaces. See the
Energy Meters start page
.
By using
Wireless AC sensors
. See the
Wireless AC Sensor manual
.
4.