6 . Verify that the two set screws, located at
the square-drive adapter, are tightened .
NOTICE
• This power mule’s rotation control switch
DOES NOT feature a “neutral” or “off”
position. Depressing the safety foot
switch will energize the tool immediately.
ALWAYS USE THE SAFETY FOOT
SWITCH TO OPERATE THE POWER
MULE.
7 .
Remove the safety foot switch/power cord
from the storage box .
7a . Plug the power head’s line cord into the
safety foot switch/power cord assembly .
7b . Place the safety foot switch in a position
that is easily accessible for the operator .
7c . Plug the safety foot switch cord into an
internally grounded electrical outlet .
The outlet shall meet the requirements
for the power head (refer to the “Power
Requirements” section on page 7 and the
power head manufacturer’s instructions) .
If an extension cord is used, refer to the
“Extension Cord Requirements” section on
page 7 for requirements .
WARNING
• The power mule shall always be
operated with a safety foot switch. If the
power mule does not contain a safety
foot switch, contact Victaulic.
Operating the power mule without a safety
foot switch may result in serious personal
injury.
ADDITIONAL TOOL SETUP INFORMATION
NOTE:
Depending on jobsite requirements, the
power head can be rotated 90° to facilitate the
grooving operation .
WARNING
• NEVER attempt to operate the power
mule without having the detent pin
installed in the power head assembly/
frame.
• NEVER operate the power head as a
hand-held tool.
Failure to follow these instructions could
result in serious personal injury.
TM-PMII_11
REV_C
TM-PMII