XX091-01-01 Rev 902 AurorAcorD
Programming
•
23
Note: The following settings, Format, Main Display Sequencing and Spot Monitor Sequencing, will not take
place if the AurorAcorD is displaying a menu, help screen or mechanical pan/tilt/zoom mode when an
alarm activates.
4. Define the display format when alarms are active: No change (stays in the current display format), Full
screen, Full Alarm, 2x2, 3x3, 4x4, mixed border or split. Display formats are shown in the
Operation chapter. All choices except Full Alarm define the format of the video when an alarm
activates, but do not select the alarm video for display on the monitors. The Full Alarm setting
will display the lowest numbered camera’s alarm video in full screen mode. When the alarm is
acknowledged, the display will return to the pre-alarm format, regardless of the Format chosen here. For
example, cameras 1, 2, and 6 go into alarm mode. Prior to any alarms being activated, the display is 4x4.
If the Format is set to Full Alarm, video from camera 1 will display in full screen mode. After the
alarm is acknowledged, the format will return to 4x4 mode. If the Format had been just Full Screen,
instead of Full Alarm, the format would change to full screen but with the pre-alarm video
displaying, which may or may not be alarm video.
5. Sequencing may be turned on or off when an alarm activates. Use the Main Display Sequence and Spot
Monitor Sequence settings to make this choice. After the alarm is acknowledged, the display will return to
the pre-alarm state, which may or may not be sequencing.
Screen Field
Choices
Default
Alarm Display Alarm Message
Main D Spot
Spot Monitor
Main Display
Off
Main
D
Spot
Alarm Text Color
Bright White, Bright Yellow, Bright Magenta, Bright Red,
Bright Cyan, Bright Green, Bright Blue, Gray, White,
Yellow, Magenta, Red, Cyan, Green, Blue, Black, Video
Bright Red
Format
Full Screen, 2x2, 3x3, Split, Mixed Border,
Full Alarm,
No Change
No Change
Main Display Sequence
On, Off, No Change
No Change
Spot Monitor Sequence
On, Off, No Change
No Change
Alarm Acknowledgement
Perform the following procedure to define alarm acknowledgment for receiver, video loss and local alarms.
Note: Motion alarms are cleared automatically 10 seconds after motion has ceased, regardless of the settings
on this screen.
1. Access the Alarm Auto Acknowledge screen as shown below.
1 Display Setup
2 Camera Setup
3 Alarm Setup
4 Serial Port Setup
5 Time/Date Setup
6 Record/Playback Setup
7 System Setup
8 Disk Functions
MAIN MENU
to Choose. to Go Back.
or 1-16 to Select.
1 A. 1 Auto Ack: Disabled
2 A. 2 Auto Ack: Enabled
3 A. 3 Auto Ack: Enabled
4 A. 4 Auto Ack: Enabled
5 A. 5 Auto Ack: Enabled
6 A. 6 Auto Ack: Enabled
7 A. 7 Auto Ack: Enabled
A. 8 Auto Ack: Enabled
ALARM AUTO ACKNOWLEDGE
to Choose. to Go Back.
or 1-16 to Select.
1 Alarm Inputs
2 Alarm Outputs
3 Alarm Display
4 Alarm Auto Acknowledge
5 Alarm On/Off Actions
6 Use Alarm Defaults
ALARM SETUP
to Choose. to Go Back.
or 1-16 to Select.
2. Define acknowledgement time for each alarm or disable the acknowledgement. If disabled, alarms must
be acknowledged manually, as discussed in the Operation chapter.
Screen Field
Choices
Default
Alarm Automatic Acknowledge
Alarm “X” Auto Ack.
Disabled, Enabled
Disabled