86
ORL-85/ORL-85P
16 S
PECIFICATIONS
G
ENERAL
SPECIFICATIONS
16
S
PECIFICATIONS
General specifications
Power meter specifications
Fiber inspection
Via P5000i Digital Probe with auto
Pass/Fail analysis
Live image
320 x 240 pixels, 8 bit gray, 10 fps
Display
High contrast 3.5" TFT color
touchscreen
Display resolution
0.01 dB / 0.001 µW
Measurement units
dB, dBm, W
Data memory
10000 measurement results
Data readout
Via client USB interface or Ethernet
Remote control capability
Via USB
Electrical interfaces
2 USB Type A, 1 USB Micro-B,
Ethernet
Power supply
Four-way power: NiMH, dry batteries,
RBP2 Li-Ion Battery Pack, PS4
Universal AC/DC Power Supply 12 V
Internal charging for
RBP2 Li-Ion Battery Pack
Recommended recalibration
interval
3 years
Size (H x W x D) ORL-85
208 x 112 x 64 mm
(8.2 x 4.4 x 2.5 in)
Weight
750 g
Operating temperature range
-5 °C to +45 °C
Storage temperature range
-25 °C to +55 °C
Adjustable wavelength range
1260 nm to 1650 nm
Calibrated wavelengths
1310 nm,
1490 nm, 1550 nm, 1625 nm
Photo diode
InGaAs
Fiber types
9/125
Display range
-85 dBm to +15 dBm
Resolution
0.01 dB, 0.001 µW
Maximum level
+15 dBm
Intrinsic uncertainty
1)
± 0.5 dB
Overall measurement
uncertainty
2)
3)
1310 nm, 1490 nm,
1550 nm, 1625 nm:
±0.60 dB
±0.15 nW
Wavelength detection
4)
Automatic switching and displaying up to
4 wavelengths simultaneously
Modulation detection
4)
270 Hz, 1 kHz, 2 kHz