Chapter 2
Configuring the reflectometry test
Configuring the test in Expert OTDR
20
User Manual
700MAN201 Rev. 002
Alarms Level
None
The alarm function is not active.
Fail
This menu lists possible major alarm thresholds that the user could
select. If results are above those thresholds, they will be highlighted
in red in the table of results, and the icon
will appear at the top
right of the screen.
If Fail is selected, select in the
Threshold
parameter to defined values either
manually or according to standards:
–
User
: define your own thresholds values for one or several elements: Splice /
Connector / Reflectance / Slope / Fiber Length Min and Max / Total Loss Min
and Max / ORL
–
TIA-568 3 / TIA-568 3.RL35
/
ISO/IEC 11801 2010 or 2014
/
ISO/IEC 14763-3
2019
/
IEC 61280-4-5 (2020)
/
Default:
Select one of this parameter to
configure the alarm thresholds with predefined values:
Figure 12
Alarms parameters
OTDR New IHM rev002.book Page 20 Jeudi, 5. mai 2022 11:50 11