Chapter 5
Power meter, VFL (Visual Fault Locator) and Talkset
Making a measurement
User Manual
77000000206 Rev. 007
71
Unit
Allows to modify the unit of power displayed (dB,
dBm, nW)
Zero
Adjustment of the Zero value when the power
meter’s optical input is closed with a plug (a
validation is required).
Click on
Exit
to go back to the
Results
page.
Pressing the
Pow. Reference
key allows to reach the following function:
Standard Reference
Selects the current result as reference value to
measure the attenuation of a link. This reference
is displayed under the measurement result until a
new reference value is chosen.
Jumper Reference
This key can be pressed when a reference in
loopback mode must be performed (see 4100
Module Series User Manual).
Making a measurement
The power meter is started up as soon as the function
is acti-
vated in the
H
OME
menu.
Power
measurement
1
Connect the light source to be tested to the rear connector (see
"Connection to the power meter" page 67
2
In the
S
ETUP
menu, choose the units dBm, dB or Watts.
3
Press the
S
TART
/S
TOP
key to start the measurement
.
The result will appear in the results page and can be memorized in
the table (see
4
Press the
S
TART
/S
TOP
key to stop the measurement.
The soft key Jumper Ref is displayed in grey and cannot be
activated if both power meter and Source are selected onto the
OTDR Module set into the Platform.
The power meter must be selected onto the Base-Unit, and the
Source onto the OTDR Module to activate the soft key and be
able to perform a reference measurement in loopback mode.
Power measurement is automatically updated in consequence. The
value «<-60 dB» is displayed when the laser is switched off and if the
source output is looped on to the power meter input.
Содержание MTS 4000 Base Unit
Страница 2: ......
Страница 4: ......
Страница 18: ...Table of Contents xiv User Manual 77000000206 Rev 007 ...
Страница 30: ...Chapter 1 Introducing the 4000 Base Unit Measurements 8 User Manual 77000000206 Rev 007 ...
Страница 44: ...Chapter 2 Starting up Troubleshooting 22 User Manual 77000000206 Rev 007 ...
Страница 86: ...Chapter 4 System set up Expert Tools 64 User Manual 77000000206 Rev 007 ...
Страница 142: ...Chapter 7 Bluetooth option Removing the Pairing 120 User Manual 77000000206 Rev 007 ...
Страница 154: ...Chapter 8 802 11 Wireless Testing 802 11 wireless results 132 User Manual 77000000206 Rev 007 ...
Страница 170: ...Chapter 9 Ethernet TE Testing Web browser 148 User Manual 77000000206 Rev 007 ...
Страница 202: ...Chapter 11 File management File editing function 180 User Manual 77000000206 Rev 007 ...
Страница 204: ...Chapter 12 Smart Access Anywhere 182 User Manual 77000000206 Rev 007 Connection information and settings page 193 ...
Страница 232: ...Chapter 13 Maintenance and Troubleshooting General information on warranty 210 User Manual 77000000206 Rev 007 ...
Страница 240: ...Chapter 14 Technical specifications Characteristics of the options 218 User Manual 77000000206 Rev 007 ...
Страница 246: ...Chapter 15 Options and accessories References of result processing software 224 User Manual 77000000206 Rev 007 ...
Страница 252: ...Index 230 User Manual 77000000206 Rev 007 ...
Страница 253: ......