IMPORTANT NOTICES
1.
The boiler only can be used for the purposes that it is destined for.
2.
The boiler only can be operated by adults who are made acquainted with this operation manual.
It is not permitted to let the children unattended by adults near the boiler being in operation. It is
not permitted to tamper with boiler in a way, which could endanger operators or eventually
roommates’ health.
3.
The boiler is not destined for the use by persons (incl. children) whose physical, sensual or
mental disability or lack of experience and knowledge prevent them from a safe use of the
appliance unless they are supervised or if they were not instructed on the use of appliance by a
person responsible for their safety.
4.
Children should be supervised in order to ensure that they do not play with the appliance.
5.
If there occurs a danger of combustible vapors or gases that are releasing and penetrating into
the boiler room or when working in a temporary fire or explosion risk (gluing the floorings,
painting works using the combustible paints etc.) the boiler must be well ahead put out of
operation before these works start.
6.
It is forbidden to use the flammable liquids for firing the boiler.
7.
It is FORBIDDEN to overheat the boiler during its operation.
8.
Open the stoking door and ash pan door only by means of plastic handles
9.
The ash pan door must not be opened during boiler operation
10. The flammable subjects mustn’t be laid on the boiler or in a distance lower than the safety
distance.
11. The flammable materials must be in a distance at least 1500 mm from the boiler when clearing
ashes from boiler.
12. When operating the boiler at the temperature lower than 60 °C there can appear the retting of
boiler and so called low-temperature corrosion which can reduce the boiler drum service life.
Therefore it is recommended to operate the boiler at temperature 60 °C and higher.
13. After the end of heating season the boiler including the smoke flues and smoke adapters must
be thoroughly cleaned. The swivel pins, smoke flap mechanism and other moving parts of boiler
must be lubricated by applying the graphite grease. Keep the boiler room clean and dry.
14. If the boiler is not in use (e.g. in summer season ) it is necessary to disconnect it from the
electrical power network due to possible damage caused by the atmospheric surge (lightning)!
15. The possible signs of corrosion on the boiler drum are not any defects and do not influence its
function.
16. In case the two-way safety equipment is signalling that boiler has been filled with the water
which does not meet the
Č
SN 077401 requirements it is necessary to treat the water in the
system so that it again meets this standard requirements.
17. During assembly, installation and operation of the appliance it is necessary to comply with
standards that apply in the relevant country of destination.
If you fail to meet these conditions you cannot requisite the guarantee repairs.