20
3.5.3 Limit switch installation – Hefaistos P1 E
1.
Connect the limit switch according to the electrical connection see. Chap. 4.8
2.
Insert the rod (9) into the left hole (A) in consoles (2). Then mount the circlip 7 (8).
3.
By means of screws M4 x 40 (4) and washers 4.3 (6) mount the limit switch (3) to the consoles (2) and
the upper part of shell (1) and secure with nuts M4 (7) and washers 4.3 (6).
4.
Screw the bolt M5x 20 (11) with washers 5.3 (10) on the rod (9) in the front upper part of the shell
(if necessary- when testing the limit switch- we can change the number of washers (10).
A – left hole of the console
1.
upper part of the shell
2.
console
3.
limit switch
4.
screw M 4 x 40
5.
washer 4,3
6.
washer 4,3
7.
nut M4
8.
console
9.
rod
10. washer 5,3
11. screw M 5 x 20
Fig. no. 11
Limit switch installation
3.5.4 Installation of cleaning tools
Use the common assembly tools and leather gloves when mounting or dismounting the brush, tip on the
spike and cleaner (if included in the delivery).