Advantages of the boiler: 

1. 

High operational reliability and long service life due to the use of high-quality grey cast iron with lamellar graphite. 

2. 

The  top-quality  structure  of  the  cast-iron  sections  with  a  decreased  weight  in comparison  to  the  previous  versions  prevents  creation  of 
condensate and, by this, a danger of low-temperature corrosion as well. 

3. 

Economic low-temperature operation without occurrence of condensate. 

4. 

High effectiveness up to 93 %. 

5. 

Reliability of regulation and safety elements. 

6. 

Equipping  with  a  flue  gases  reverse  flow  safety  device  that  in  case  of  insufficient  chimney  draught  switches-off  the  boiler;  it  helps  to 
increase the boiler safety. 

7. 

A possibility of connection of some of superior regulations on the base of the customer's requirements to the level of heat comfort. 

8. 

Two-stage working operation of the boiler with help of the HIGH-LOW coil. 

9. 

Besides  of  that,  VIADRUS  GARDE  G42  ECO  boilers  are  combined  with  a  possibility  of  connection  of  VIADRUS  
OV 100 L stationary water heater.  

10. 

Low content of harmful substances in flue gases are far lower than the value specified in Directive of the Ministry of Environment No. 05-
97  "Ecologically  friendly  product"  and  meets  the  requirements  of  the  strictest  European  norms,  for  example,  even  the  border  of  "Blue 
angel". 

11. 

A high combustion chamber enables clean flame combustion.  

12. 

In case of the use of  the pump thermostat, monitoring of the minimum temperature of boiler water is ensured.  

13. 

Simple manipulation and maintenance. The boiler drum can be easily mechanically cleaned-up with help of an attached brush.  

14. 

In  case  of  equipping  with  a  withdrawal  flue-gas  fan,  which  enables  exhaust  of  flue  gases  to  the  outdoor  space  directly  through  the 
external wall, the boiler can be installed into a premise where there is no possibility to connect the boiler to a chimney. 

 
 

Boiler's technical data  

  

Tab. №. 2 

Boiler's sizes, operating temperature and electrical parameters 

Number of sections 

pcs 

Boiler design 

 

B

11BS

 in NG design  

Consumer category 

 

II

2H3P

 

Heating power  

kW 

12-17 

18-26 

22-30 

Weight 

kg 

75 

100 

122 

146 

Water content 

9.2 

11.4 

13.6 

Chimney throat diameter 

mm 

80 

110 

130 

160 

Boiler sizes - width 

mm 

335 

420 

505 

590 

 - depth x height 

mm 

758 

× 957 

Operating water overpressure 

kPa (bar) 

400 (4) 

Testing water overpressure 

kPa (bar) 

800 (8) 

Maximum heating water temperature 

°C 

85 

Minimum heating water temperature 

°C 

45 

Minimum return water temperature 

°C 

45 (25*) 

Noise level 

dB 

max. 65 dB (A) 

Chimney draught 

mbar 

min. 0.025 

Boiler connections - heating water 

Js 

1

“ 

 - return water 

Js 

1

“ 

 - gas 

Js 

1/2" 

Connecting voltage 

 

1/N/PE 230 V AC 50 Hz TN-S 

Electrical input 

kW 

0.1 

Electric cover 

 

IP 40 

* In the observance of the minimum temperature of heating water 

 

Tab. №. 3 

Boiler's thermal-technical parameters  

(calorific value 34,16 MJ. m

-3

, gas temperature 15°C and air barometric pressure 1013,25 mbar)

  

Number of sections 

pcs 

Nominal heating power - maximum 

kW 

17 

26 

30 

Nominal heating power - minimum 

kW 

12 

18 

22 

Nominal heating input - maximum 

kW 

8.87 

18.52 

28.32 

33 

Nominal heating input - minimum 

kW 

12.95 

19.25 

24.42 

Volume flow rate of gas at the maximum heating power 

m

3

.hour

-1

 

0.935 

1.952 

2.985 

3.46 

Volume flow rate of gas at the minimum heating power 

m

3

.hour

-1

 

1.365 

2.029 

2.57 

Volume flow rate of gas at the maximum heating power 

dm

3

.min

-1

 

15.58 

32.53 

49.75 

57.81 

Volume flow rate of gas at the minimum heating power 

dm

3

.min

-1

 

22.75 

33.82 

42.91 

Efficiency at the maximum heating power  

90 

– 92 

Efficiency at the minimum heating power  

90 

– 93.5 

NOx Class 

 

Temperature of flue gases in the flue gas ducting at the maximum heating power 

°C 

105 

– 125 

Temperature of flue gases in the flue gas ducting at the minimum heating power 

°C 

80 

– 100 

Real quantity of dry flue gases at the maximum heating power 

m

3

.m

-3

 

17.38 

23.33 

19.71 

23.89 

Real quantity of dry flue gases at the minimum heating power 

m

3

.m

-3

 

25.09 

27.10 

28.67 

Connecting gas overpressure 

mbar 

20 

Gas overpressure on nozzles of the burner at the maximum heating power 

mbar 

13.2 

14.9 

14.8 

14.7 

Gas overpressure on nozzles of the burner at the minimum heating power 

mbar 

7.6 

9.8 

Number of nozzles 

pcs 

Nozzle diameter 

mm 

2.45 

2.45 

2.20 

2.20 

Remark: In case of a single-stage valve, its heating power is being set in the production plant to the maximum. 

Содержание GARD G42 ECO

Страница 1: ...GB_2018_03...

Страница 2: ...ment 24 10 Delivery and assembly 25 10 1 Delivery and accessories content 25 10 2 Mounting procedure 25 11 Commissioning instructions for contractual service organizations 27 11 1 Verification activit...

Страница 3: ...s it is equipped with a safety device for prevention of flue gas reverse motion A two sections and three sections design is suitable for reconstruction of heat sources in separate dwelling units for s...

Страница 4: ...ating power kW 8 12 17 18 26 22 30 Weight kg 75 100 122 146 Water content l 7 9 2 11 4 13 6 Chimney throat diameter mm 80 110 130 160 Boiler sizes width mm 335 420 505 590 depth x height mm 758 957 Op...

Страница 5: ...ing of the boiler is painted with high quality komaxit painting The atmospheric burner consisted of low emission oval shaped burner pipes of new type is made of anti corrosion steel with high operatio...

Страница 6: ...cladding 10 cladding rear part 11 electric panel bracket 12 electric panel 13 safety flue gases thermostat 14 safety operational thermostat 15 boiler thermostat with a turning knob 16 thermo manomete...

Страница 7: ...the safety and boiler thermostats eventually the pump thermostat of the thermometer are placed in the well of the left outer section and the back pressure valve that is placed in the upper part of the...

Страница 8: ...tion pilot burner is not combusted during the safety time Ts 55 s Ts 25 s SIT Ts 60 s then the blocking automatics will be connected If flame is extinguished during normal operation the igniting autom...

Страница 9: ...LURE SIGNALLING B 1 SAFETY THERMOSTAT BT4 BOILER THERMOSTAT BT6 OUTDOOR THERMOSTAT S2 LOW NOMINAL POWER SWITCH Y3 2 VALVE COIL M9 EXHAUSTING VENTILATOR E1 IGNITION ELECTRODE E2 IONIZATION ELECTRODE Y1...

Страница 10: ...way valve Circulation pump Valve 2 coil Circulation pump thermostat DHW heater thermostat Room thermostat ELECTRIC PANEL Conductors colors GNYE yellow green RD red BK black BN brown BU blue LEGEND Z1...

Страница 11: ...K 4100 Q 2003 B GAS VALVE E1 IGNITING ELECTRODE E2 IONIZATION ELECTRODE BT2 FLUE GASES THERMOSTAT BT1 SAFETY THERMOSTAT BT4 OPERATION THERMOSTAT S1 MAIN SWITCH H1 BOILER UNDER VOLTAGE SIGNALLING H2 FA...

Страница 12: ...AFETY THERMOSTAT BT4 BOILER THERMOSTAT BT6 OUTDOOR THERMOSTAT S2 LOW NOMINAL POWER SWITCH Y3 2 VALVE COIL M9 EXHAUSTING VENTILATOR E1 IGNITION ELECTRODE E2 IONIZATION ELECTRODE Y1 VK 4100 Q 2003 B GAS...

Страница 13: ...entilator Three way valve Circulation pump Circulation pump thermostat DHW heater thermostat Room thermostat ELECTRIC PANEL Conductors colors GNYE yellow green RD red BK black BN brown BU blue LEGEND...

Страница 14: ...AUTOMATICS Y1 VK 4100 A 1002 GAS VALVE E1 IGNITING ELECTRODE E2 IONIZATION ELECTRODE BT2 FLUE GASES THERMOSTAT BT1 SAFETY THERMOSTAT BT4 OPERATION THERMOSTAT S1 MAIN SWITCH H1 BOILER UNDER VOLTAGE SI...

Страница 15: ...IGNALLING B 1 SAFETY THERMOSTAT BT4 BOILER THERMOSTAT BT6 OUTDOOR THERMOSTAT S2 LOW NOMINAL POWER SWITCH Y3 2 VALVE COIL M9 EXHAUSTING VENTILATOR E1 IGNITION ELECTRODE E2 IONIZATION ELECTRODE Y1 SIGMA...

Страница 16: ...way valve Circulation pump Valve 2 coil Circulation pump thermostat DHW heater thermostat Room thermostat ELECTRIC PANEL Conductors colors GNYE yellow green RD red BK black BN brown BU blue LEGEND Z1...

Страница 17: ...GMA 843 GAS VALVE E1 IGNITING ELECTRODE E2 IONIZATION ELECTRODE BT2 FLUE GASES THERMOSTAT BT1 SAFETY THERMOSTAT BT4 OPERATION THERMOSTAT S1 MAIN SWITCH H1 BOILER UNDER VOLTAGE SIGNALLING H2 FAILURE SI...

Страница 18: ...boiler with an equitherm regulator the pump operation is controlled according to the regulator program Fig 14 Characteristics of Wilo Yonos Para RS 15 7 5 pump 7 Stack heaters for domestic hot water 7...

Страница 19: ...lower supply rate the heating time of domestic hot water will be longer Important warning Set the heater thermostat at the maximum temperature of 60 C remark Regulations in Czech Republic do not allo...

Страница 20: ...anometer probe well 10 support 11 side wall part of the cladding 12 rear part of the cladding 13 electric panel bracket 14 upper part of the cladding 15 front part of the cladding 16 heating water out...

Страница 21: ...o fig 19 provided the boiler is designed so that it complies with observation of the maximum height of H 1 5 m and calculations according to table No 7 The pressure loss is minimum in this design Fig...

Страница 22: ...80 1 m with sealing 1 K 45 Elbow 45 O M with sealing 2 5 K 90 Elbow 90 O M with sealing 3 O 90 Bend 90 Rs 100 O M with sealing 2 TK 80 Pipe of 1 m with an end piece 2 M 80 Internal external cuff R 60...

Страница 23: ...provision of safety Protection against electric shock SN 33 2000 5 51 ed 3 Low voltage electric installation Part 5 51 Selection and construction of electric devices General regulations SN 33 2130 ed...

Страница 24: ...s included in the reaction of fire extract from SN EN 13501 1 A1 A1 incombustible Granite sandstone concrete bricks ceramic tiles mortars fireproof plasters A2 hardly combustible Acumin izumin herakli...

Страница 25: ...ly still wrapped in protective packing If this is not possible due to the lack of space convey the boiler without the packing holding it by its base plate In no case is allowed to lift the boiler by t...

Страница 26: ...be deposited in the distributions or the heating radiators and consequently could cause a damage of the pump Water serving for watering the heating system has to be clean and colorless without suspen...

Страница 27: ...t is recommended to set temperature to 85 C heater thermostat if connected 0 90 C for a sufficiently fast hot water heating the TK boiler thermostat must be set to 85 C 3 Gas input pressure before ent...

Страница 28: ...iler 2 gas valve 1 Put the boiler into operation 2 Measure the gas input pressure 3 Before itself wait a while till operational pressure conditions on the burner are being stabled 4 If an outdoor ther...

Страница 29: ...lve is set by the manufacturer to the slowest start up see fig No 32 the MIN curve If you need to change the opening characteristics it is possible to perform setting according to the following points...

Страница 30: ...ure from the low to nominal value by means of an outdoor thermostat If the power switch is in the positions I the boiler in case of outdoor temperature higher than 0 C will be operated with the low po...

Страница 31: ...Check the burner tubes choking In case they are fouled dismount the ignition pilot burner Fig No 3 or 4 by means of a steel brush clean slightly the burner tubes perforation remove dust with help of...

Страница 32: ...bout 10 min 9 Don t put any objects made of flammable material on the boiler and within a distance smaller than the safe distance from it see chapter no 9 2 10 The user is obliged to put a professiona...

Страница 33: ...out in case of fine impurities the dimensions of which are the same as the filter mesh diameter the whole gas valve must be exchanged Boiler cannot be ignited the safety thermostat is switched off on...

Страница 34: ...operator VIADRUS a s provides an extended warranty period for the boiler drum of the boiler for 60 months from the sale date but not longer than 66 months from the dispatch date from VIADRUS a s The c...

Страница 35: ...wer and high temperature mode 4 90 93 At 30 of nominal heating power and low temperature mode P1 2 4 kW At 30 of nominal heating power and low temperature mode 1 89 21 Auxiliary electric energy consum...

Страница 36: ...d low temperature mode 1 90 69 Auxiliary electric energy consumption Other items At full load elmax 0 010 kW Heat loss in standby mode Pstby 0 099 kW At partial load elmin 0 003 kW Electric energy con...

Страница 37: ...d low temperature mode 1 90 79 Auxiliary electric energy consumption Other items At full load elmax 0 010 kW Heat loss in standby mode Pstby 0 095 kW At partial load elmin 0 003 kW Electric energy con...

Страница 38: ...and low temperature mode 1 90 76 Auxiliary electric energy consumption Other items At full load elmax 0 010 kW Heat loss in standby mode Pstby 0 114 kW At partial load elmin 0 003 kW Electric energy c...

Страница 39: ...tion of resources SN EN 13428 SN EN 13427 YES 2 Repeated use SN EN 13429 NO 3 Material recycling SN EN 13430 YES NO i 4 Energy evaluation SN EN 13431 YES NO a 5 The use by composting and biodegradatio...

Страница 40: ...ificate for the customer the user The record of performed warranty and after warranty repairs and regular annual checks of the product Record date Performed activity Contractual service organization s...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ......

Отзывы: