11
5.2
Positioning possibilities
Boiler can be installed in basic environment AA5/AB5 according to
Č
SN 33 2000-1 ed. 2. It must not
be installed in zones 0,1,2 according to
Č
SN 33 2000-7-701 ed. 2.
The boiler is equipped with a movable mains supply and a plug. The boiler must be according to
EN 60 335 – 1 ed. 2 Art. 7.12.4 positioned in a way making sure that the plug is accessible.
The installation of the boiler must comply with all requirements of
Č
SN 06 1008.
Boilers positioning with regard to the fire regulations:
1. Positioning on the floor made of incombustible material
−
Install boiler on fireproof thermally bottom exceeding the boiler platform by 20 mm on the sides and only
up to the boiler drum depth.
−
If the boiler is positioned in a cellar we recommend to install it on a retaining wall (bedding) minimum
50 mm high
2. A safe distance from combustible materials
−
when installing and operating the boiler it is necessary to keep a safety distance of 200 mm from the
materials of combustibility grade A1, A2, B and C (D);
−
for easily combustible materials of combustibility grade E (F), which quickly burn and burn themselves
even after removal of ignition source (such as paper, cardboard, asphalt and tar paper, wood and wood-
fiber boards, plastics, floor coverings) the safe distance has to be doubled, i.e. to 400 mm;
−
safe distance should be doubled as bulb where the grade of reaction to fire has not been proved.
Tab. no. 6 Grade of reaction to fire
Grade of reaction to fire
Examples of building materials and products included in the reaction to fire
(Extract from EN 13 501-1 + A1)
A1 – incombustible
Granite, sandstone, concrete, bricks, ceramic tiles, mortars, fireproof plasters, …
A2 – combustible with difficulty acumin, izumin, heraklit, lignos, boards and basalt felt, fibreglass boards,...
B – hardly combustible
Beech and oak wood, hobrex boards, plywood, werzalit, umakart, sirkolit,...
C (D) – medium combustible
Pinewood, larch, whitewood, chipboard and cork boards, rubber flooring,...
E (F) – easily combustible
Asphaltboard, fibreboards, cellulose materials, polyurethane, polystyrene,
polyethylene, PVC,…
Number of sections
2
3
4
5
6
TOEL – output in kW
18-25
25-37
37-46
46-60
60-80
Natural gas– output in kW
14-22
22-33
33-46
46-60
60-80
L
488
638
788
938
1088
H (max.)
260
260
320
320
320
Fig. no. 8
Positioning of G 50 boilers in boiler room