Information for the user – Fine adjustments detail 5/5
Ventilation function
The ventilation function will switch on the connected ventilation
if the set temperature threshold is exceeded.
Function may only be activated for the ventilation type of control
system.
Setting temperature threshold
In this menu, you can set a temperature threshold. If the
temperature exceeds this level the connected ventilation will be
switched on. Use the buttons and to set the desired
temperature threshold.
Programmable range:
off
, 15°C – 35°C
I
NOTE!
In case of TE Indoor and TE Outdoor assignment, display
of temperature is not possible. Following temperature
settings are disabled.
Press
to return to the detail 5/5 menu.
Press
for the temperature unit menu.
Setting reset delay
The reset delay delays the switching off of the ventilation after
the temperature drops below the set threshold. A reset delay
can be set (in minutes) using the and buttons.
Programmable range: 1 – 60 minutes
Press
to return to the temperature threshold menu.
Press
for the temperature unit.
Setting temperature unit
In this menu, you have the option of displaying the temperature
unit in degrees Celsius (°C), kelvin (K) or Fahrenheit (F). To set
the temperature unit, press the appropriate symbol. The symbol
will then appear by the selected unit.
Press
to return to the reset delay menu.
Press
for the detail 5/5 menu.