POWER / DATA CABLE
COLOR
DESCRIPTION
Red
DC positive (+) (12-24 volts).
Always use a 2A
fuse or circuit breaker.
Do not connect directly
to battery. If you must extend the power
connections use high quality pre-tinned marine
grade wire which is at least
16 AWG (1.5mm
2
)
.
Black
DC negative (-)
Gray
NMEA 0183 out (+) A
Yellow
NMEA 0183 out (-) B
Green
NMEA 0183 in (+) A
White
NMEA 0183 in (-) B
Blue
External alarm. When an alarm is triggered and
the external alarm is enabled this wire will have
the input voltage (from the red wire) applied,
current limited to 150mA. You can use this to
provide power to an external buzzer, light or
other signaling device.
(Do not connect brown, orange or pink wire)
NMEA OUT (+) A
CHART PLOTTER
NMEA OUT (-) B
NMEA IN (+) A
NMEA IN (-) B
HEADING SENSOR
NMEA OUT (+) A
NMEA OUT (-) B
NMEA IN (+) A
NMEA IN (-) B
(Gray)
(Yellow)
(Green)
(White)
38400 Baud
4800 Baud
DC NEGATIVE / GROUND
(Blue)
EXTERNAL ALARM
+
-
A 2m (6 ½ft) cable with attached 10 pin connector is supplied for connecting
the WatchMate to power, other devices over NMEA 0183 and an external alarm.
You may extend this cable as necessary.
• Check you have the VHF antenna connected before connecting to power.
• Fully engage the locking ring to ensure a watertight seal.
• Received NMEA 0183 data is output on USB.