Vertiv Intelligent Rack PDU
Page 30
4.2.2. NETW ORK SETUP
The Monitored Vertiv Upgradeable PDU has a default IP address for initial setup and access. Once you
have assigned an IP address, the default IP address will no longer be active. To restore the default IP ad-
dress and reset all user-account information, if the user-assigned address or passwords are lost or forgot-
ten, press and hold the network-reset button located below the Ethernet port for 15 seconds. Holding the
center button of the LED display for 10 seconds will also reset the network and user account information.
To completely erase ALL of the user settings and restore the unit back to its factory-default state, discon-
nect power from the PDU, then press and hold the network-reset button while powering up the PDU.
The Network page (located under the System Tab) allows you to assign the network properties manually,
or use DHCP to connect to your network. Access to the unit requires the IP address to be known. Use of
a static IP or a reserved DHCP is recommended. The default address is shown on the front of the unit:
Table 2-15
Default IP Address
IP Address:
192.168.123.123
Subnet Mask:
255.255.255.0
Gateway:
192.168.123.1
To access the unit for the first time, you will need to temporarily change your computer's network settings
to match the 192.168.123. xxx subnet. To set up the unit, connect it to your computer's Ethernet port,
then follow the appropriate instructions for your computer's operating system.
Windows
·
Windows 2000 / XP / Server 2003:
Click the
Start
button, choose
Settings
, then
Network Connections.
·
Windows 7 / Server 2008:
Click the
Start
button, then choose
Control Panel
>>
Adjust Your Computer's Settings
>>
View Net-
work Status and Tasks
>>
Change Adapter Settings
.
(Alternatively, on some Windows 7 machines, this may be
Start
, then
Settings
>>
Control Panel
>>
Net-
work and Sharing Center
>>
Change Adapter Settings
.)
·
Windows 8 / Server 2012:
Move the mouse cursor to the bottom or top right corner of the screen, click the
Settings
icon, then select
Control Panel
. Change the view type from
Category
to
Large
or
Small Icons
if necessary, then select
Network and Sharing Center
, then
Change Adapter Settings
.
Содержание VP7811B
Страница 21: ...Vertiv Intelligent Rack PDU Page 21 4 2 1 2 MINI L BRACKETS SLB 4 Figure 2 2 Mini L Brackets ...
Страница 28: ...Vertiv Intelligent Rack PDU Page 28 4 2 1 13 CABLE MOUNT BRACKETS CMB 1 Figure 2 13 Cable Mount Brackets ...
Страница 53: ...Vertiv Intelligent Rack PDU Page 53 Figure 3 12 IMD Removal Steps ...
Страница 79: ...Vertiv Intelligent Rack PDU Page 79 Thank You For Purchasing Your Vertiv Product VertivCo com geist ...