VFI33 Vent Free Gas Fireplace System
20307670
7
PRE-INSTALLATION INFORMATION
GETTING STARTED
Make sure you have received all parts
Check your packing list to verify that all listed parts have
been received. You should have the following:
•
Installation/Operating instructions
•
33" unvented gas heater
•
Canopy
•
Volcanic rock and rock wool (traditional sets only)
•
Stone and fi reglass kit (contemporary sets only)
•
Two (2) anchoring screws
•
Mounting screws for canopy
Accessories required to fi nish the installation:
One of two surrounds:
•
VFICFSS
Black small surround 33"H x 43"W
•
VFICFSL
Black large surround 36"H x 50"W
One of three fi rebox liners:
•
FBVFIC(M/LR) Firebrick
•
BLPVFIC
Black porcelain panels
•
BMGVFIC
Black Magic glass panels
WHAT YOU WILL NEED FOR INSTALLATION
You must have the following items available before pro-
ceeding with installation…
•
External regulator (for propane / L.P.G. and 1/2 lb.
Natural Gas systems only)
•
Piping which complies with local codes
•
Sediment
trap
•
Tee
joint
•
Pipe wrench or appropriate size crescent wrench
set
•
Phillips head screwdriver
•
Drill with 5/32" bit
•
Surround
•
Manual shutoff valve
•
Pipe sealant approved for use with liquid propane
(resistant to sulfur compounds)
FRAMING DIMENSIONS
If unit is to be “built in,” fi replace framing can be built before
or after the appliance is set in place.
BE SURE THAT ALL
PACKING MATERIAL HAS BEEN REMOVED FROM
THE UNDERSIDE OF THE UNIT PRIOR TO SETTING
THE FIREBOX IN PLACE.
Construct fi replace framing
following Figure 2. Refer to Figure 5 on Page 9 for fi replace
dimensions. The framing headers may not rest directly on
top of the fi rebox.
The fi replace may be installed directly on a combustible
fl oor or a raised platform of an appropriate height. Do
not place fi replace on carpeting, vinyl, tile or other soft
fl oor coverings. It may, however, be placed on fl at wood,
plywood, particle board or other hard surfaces. Be sure
fi replace rests on a solid continuous fl oor or platform with
appropriate framing for support and so that no cold air can
enter from under the fi rebox. Your vent-free fi replace must
be mounted to the fl oor or the fi replace hearth.
The millivolt controlled version of this heater is the only
style designed to be operated with optional devices for
ON/OFF functions. The following options may be used
with the millivolt controlled heater. These options are not
packaged with the log set.
•
Hand held Remote with Receiver
•
Wall switch with 15' wire.
•
Hand held Thermostat Remote with Receiver
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you have
all parts in good condition.
•
Handle the gas log burner assembly by the
grate only. Do not pick the unit up by the
burners.
•
Gloves are recommended when handling
ceramic fi ber logs to prevent skin irritation
from loose fi bers. Logs are fragile — handle
with care.
WARNING:
WARNING—Do not install the heater:
•
Where curtains, furniture, clothing, or
other fl ammable objects are less than
42" from the front of the heater.
•
In high traffi c areas.
•
In windy or drafty areas.
WARNING: If the area in which the heater
is operated does not meet the required
volume for indoor combustion air, combustion
and ventilation air shall be provided by one of
the methods described in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International
Fuel Gas Code or applicable local codes.